TC-S5713 Emergency Start/Abort Button Features of Emergency Start/Abort Button Non-polarized two bus system Installed at the entrance of the protected area When fire occurs,press emergency start/abortswitch Special key resettable L1,L2:non-polarized two bus input RVS twisted pair is selected for L1 and L2,and thecross-sectional area is not less than 1.0mm2 Loop impedance is less than 40Q,otherwise the wire diameter should be enlarged. Specification of TC-S5713 Energency Start/Abort Switch Operating Volate DC 24V Operating Current ≤250mA Coding method Electronic coding, coding range: can be set between 31~38 Coding method Temperature:-10~+55℃; relative humidity≤95% (40±2℃) Atomspheric pressure: 86Kpa~106Kpa Dimension 298mm*30mm*135mm (with base) Mounting hole distance 60mm Material of enclosure ABS
$15.00The TX7140 Intelligent Manual Call point use a non-breakable glass which is designed to press under light pressure triggering the call point into an alarm condition, with LED indicator mounted onto the front face to simplify the location of an operated call point. Safe to press and no hammer is required. The protected flap on the lower part is used for reset through supplied special tool.
Through-line aperture: 73mm; main circuit rated operating current: less than 315A Dimensions: 160mm × 118mm × 45mm Works with 2-lines bus loop JB-DH-TC5600 Electrical Fire Monitoring Equipment. TC-DH01B-70 Residual current electrical fire monitoring detector has built-in processor can receive the signal from the transformer and handle those signals into two forms of normality and alarming, both of which will be transmitted to the electrical fire monitor control panel. Technical Features 1. Operating Voltage: Pulse voltage of circuit loop: Loop 24V Available range: 16V~30V 2. Operating current: Standby current≤0.4mA Alarming current≤0.7mA 3. Rated alarming current: 200mA~1000mA, step-size 1mA 4. Encoding mode: electrical addressable mode. It takes one site on the loop. And an addressable code could be any in the range of 1~255. 5. Cabling: connecting with the monitoring devices through signal nonpolar two-line loop. 6. Aperture of wires: 73mm 7. Rated operating current of main loop: less than 315A. 8. Rated frequency of wires: 50Hz/60Hz 9. Ambient environment: Temperature: -10℃~+55℃ Relative humidity≤95%, non-condensing 10. Dimension: 160mm×118mm×45mm 11. Enclosure material: ABS plastic 12. Ingress Protection Rating: IP30 13. Weight: about 1kg
$40.00DC24V LPCB Approved Addressable fire alarm button ressetable manual fire alarm call point works with TC series addressable fire alarm system. Installed in public places; when there is a fire, pressing the frangible element on this MCP can send fire signal to fire alarm control panel Alarm by pressing, reset by a special key Non-polarized two-wire to the control panel Reusable Approvals:LPCB(EN54-7) CE Technical Specifications Operating voltage Loop 24V(18.5V~26V) Operating current Standby current: ≤0.2mA;Alarm current: ≤0.8mA Operating Environment Indoor Temperature: -10°C~+55°C;Relative Humidity: ≤95%, non-condensing Indicator Red. Flashes about every 3s when polling;Illuminates after in alarm Coding method Electronically coding Code range 1~255 Material and color of enclosure ABS; Red Weight About 120g (with base) Mounting hole distance 60mm Dimension (L×W×H) 95mm×44mm×95mm (with base) Product installation manual and video atalarm button
$16.80TC5402W wireless heat detector is an intelligent household fire detector with high- precision thermostor as the sensor, which can be used together with the wireless fire alarm control panel. The detector uses advanced wireless transceiver technology and high-integration micro-processing chip to process data. Technical Data All data is supplied subject to change without notice. Specifications are typical at 24V, 25℃ and 50% RH unless otherwise stated. Battery CR17450 3V Operating current monitoring current≤3uA , alarm current≤18mA Coding method automatically assigned when networking Radio frequency transmit power<20dBm Frequency band 470MHz Communication distance ≤500m Communication method 470MHz FSK coded bidirectional Operating environment temperature 10℃~+55℃ relative humidity ≤95% Dimension 100mm*54mm(with base) Weight 110g Using advanced wireless transceiver technology, signal transmission can be completed without wiring, and the project is simple and convenient. It adopts 470MHz communication and FSK coding technology, which has strong anti- interference ability and long transmission distance Low-voltage battery detection, reminding the user to replace the battery when it is insufficient to maintain the normal operation of the detector.
$22.50Back lit LED displaying all the information Display Capacity: Max 1024 pieces of scrolling information Simultaneous audible and visible alarming signals with the control panel MUTE, UP, DOWN and BROWSE operational keys are available
The fire alarm system programmer is used for TX brand addressable fire alarm control panel. With the programmer, the smoke detector, heat detector, gas sensor, manual fire alarm button, manual call point and input output module can be encoded with address. After all fire detectors are encoded, it can be installed on ceiling, wall of protected areas and warning areas. Each detector has unique address and when alarm occurs, from the displayer and alarm panel, the alarm point will be known immediately. You can easy program detectors with fire alarm system programmer.
Addressable fire alarm system LPCB EAC certificate professional fire security equipment. Heat Detector LPCB CE EN54 works with TC-5109 Advanced single-chip microcomputer technology Non-polarized two-wire Indoor garage, kitchen, boiler room, generator room, drying room and other places Approvals:LPCB(EN54-5) CE Technical Specifications Operating voltage Loop 24V(18.5V~26V) Operating current Standby current: ≤0.3mA;Alarm current: ≤0.8mA Operating Environment Temperature: -10°C~+50°C;Relative Humidity: ≤95%, non-condensing Indicator Red,Flashes when polling,Illuminates in alarm Ingress protection rating IP33 Material and color of enclosure ABS; Milky white Coding method Electronically coding Code range 1~255 Weight About 110g Mounting hole distance 60mm Dimension 100mm×50mm (with base) Product installation manual and video at heat detector
$16.80Fire alarm siren works with TC series addressable fire alarm system TC-5109 LPCB alarm panel. LPCB certified addressablel horn strobe flash and sounder Installed in public places A kind of audio and visual alarm device used to warn people in field when fire occurs Four wires:non-polarized signal two-wire, and non-polarized DC24V power two-wire Built-in microprocessor Self-diagnostic function Electronically coding Approvals:LPCB(EN54-3) CE Technical Specifications Operating voltage Loop: 24V (16V~28V);Power: DC24V (DC19V~DC28V) Standby current Loop: ≤0.2mA;Power: ≤0.5mA Active current Loop: ≤1.5mA;Power: ≤50mA Operating Environment Indoor (Non-residential);Temperature: -10°C~+50°C; Relative Humidity: ≤95%(40±2°C) Sound level 80dB~115dB (A weighted) Pitch shift periodic 3.5S~4.5S Basic flashing frequency 1Hz~2Hz Weight 200g Dimension (L×W×H) 115mm×55.3mm×140mm Product installation manual and video can be found at fire horn
$18.50Electrical fire monitoring system residual current detector. Built-in processor can receive the signal from transformer and handle those signal into two forms as normality and alarming, both of which will be transmitted to the electrical fire monitoring equipment. The microprocessor will transmit the mode status of normality or alarming to monitoring devices. How to use electric fire monitor equipment and how to install? Technical Features 1. Operating Voltage: Pulse voltage of circuit loop: Loop 24V Available range: 16V~30V 2. Operating current: Standby current≤0.4mA Alarming current≤0.7mA 3. Rated alarming current: 200mA~1000mA, step-size 1mA 4. Encoding mode: electrical addressable mode. It takes one site on the loop. And an addressable code could be any in the range of 1~255. 5. Cabling: connecting with the monitoring devices through signal nonpolar two-line loop. 6. Aperture of wires: 93mm 7. Rated operating current of main loop: less than 630A. 8. Rated frequency of wires: 50Hz/60Hz 9. Ambient environment: Temperature: -10℃~+55℃ Relative humidity≤95%, non-condensing 10. Dimension: 188mm × 145mm × 45mm 11. Enclosure material: ABS plastic 12. Ingress Protection Rating: IP30 13. Weight: about 1.3kg
$55.00TCSG5416W wireless sounder strobe is suitable for installation in public places, factories and other environments, and is used together with JB-TB- TC5126W wireless fire alarm control panel. When the control panel receives the fire alarm instructions from other fire alarm devices, the control panel starts the alarm through wireless signals, and the alarm sends out sound and light signals to achieve the purpose of audible and visual alarm. Technical Data All data is supplied subject to change without notice. Specifications are typical at 24V, 25℃ and 50% RH unless otherwise stated. Battery CR17450-2-080-02 Rated Operating Voltage DC3V Operating current monitoring current≤45uA , alarm current≤240mA Sound level 75dB~115dB Coding method automatically assigned when networking Radio frequency transmit power<20dBm Communication method 470MHz FSK coded bidirectional Communication distance ≤500m Operating environment temperature 10℃~+55℃ relative humidity ≤95% Dimension 101mm*137mm*43mm Weight 170g The 470MHz wireless communication technology is adopted, and no embedded wiring is needed, so the engineering installation is convenient and quick; With battery low voltage detection function, it can reflect the battery power situation in time; The microprocessor is used to realize signal processing, and the digital signal is used to communicate with the control panel, which works stabely and reliably, and has a good ability to suppress electromagnetic interference.
$38.00TCMK5265 Addressable I/O Module non-polarized two bus,ultra-low power consumption,no need to add DC24V power supply passive outputvv input and output have isolating loop to effectively filter out external interference 1.Fix the base with two tapping screws,and then connect loop to terminals(polarity-insensitive).After thebase is fixed firmly,rotate the bottom of detector and base clockwise,and then the detector will be fitted tothe base. 2.Wiring instructions:RVS twisted pair with cross-sectional area≥1.0mm2 should be selected for the secondbus of the detector,which should be laid through metal pipe or flame retardant pipe.The length of theconnecting wire should be limited to the single bus resistance≤20Q,otherwise the wire diameter should beincreased. Rated operating voltage Loop:24V(14V~28V); Operating current Monitoring current: ≤ 0.2mA start current: ≤ 0.5mA Operating Environment Temperature:-10℃~+55℃; Relative Humidity:≤95% non-condensing Input supervisory external loop Open circuit occurs when normally open terminal supervising externalloop (short circuit is an action signal), the module will send a fault signalto the control panel. Material and color ABS;Porcelain white Output supervisory external loop Short circuit or open circuit on the output loop occurs, the module will send a fault signal to the contaol panel Weight 147g Mounting hole distance 60mm Dimension(L×W×H) 86mm×38mm×86mm(with base)
$20.00Residual Current Electrical Fire Monitoring Detector TC-DH01B-J225 Through-line aperture: 225 × 56mm main circuit rated operating current: less than 630A Dimensions: 296mm × 166mm × 45mm Standard: GB14287.2-2014 "Electric Fire Monitoring Systems - Part 2: Residual Current Electric Fire Detectors” The Detector builds up an electrical fire monitoring system with our productions of JB-DH-TC5600 Electrical Fire Monitoring Equipment, TC-DH12A Combined Electrical Fire Monitoring Detector and TC-DH230 Combined Electrical Fire Monitoring Detector. The Detector can realize the function of leakage test, temperature test and output controlling by connecting with JB-DH-TC5600 Electrical Fire Monitoring Equipment through two-line loops. It can also connect with many other kinds of residual current transformers to realize stable and reliable operating. Electrical fire monitoring system can effectively prevent electrical fires and reduce losses. Technical Specifications: 1. Operating Voltage: Pulse voltage of circuit loop: Loop 24V Available range: 16V~30V 2. Operating current: Standby current≤0.4mA Alarming current≤0.7mA 3. Rated alarming current: 200mA~1000mA, step-size 1mA 4. Encoding mode: electrical addressable mode. It takes one site on the loop. And an addressable code could be any in the range of 1~255. 5. Cabling: connecting with the monitoring devices through signal nonpolar two-line loop. 6. Aperture of wires: 225mm×56mm 7. Rated operating current of main loop: less than 630A. 8. Rated frequency of wires: 50Hz/60Hz 9. Ambient environment: Temperature: -10℃~+55℃ Relative humidity≤95%, non-condensing 10. Dimension: 296mm×166mm×45mm 11. Enclosure material: ABS plastic 12. Ingress Protection Rating: IP30 13. Weight: about 3kg
$60.00Addressable fire alarm system TC-5109 compatible Single I/O Module LPCB intelligent Module Designed to connect with linkage devices of fire alarm controlpanel, such as exhaust valve, air valve, fire damper etc., and can receive feedback signal from device Non-polarized two-wire Active and passive output The input terminal can be in field set to normally open detecting wire or self-feedback mode, which can be connected with passive contact Approvals:LPCB(EN54-18) CE Technical Specifications Operating voltage Loop:24V (18.5V~26V);Power: DC24V (DC19V~DC28V) Standby current Loop: ≤0.2mA;Power: ≤2mA Starting current Loop: ≤2mA;Power: ≤22mA Operating Environment Temperature: -10°C~+55°C;Relative Humidity: ≤95%, non-condensing Output capacity Passive:Capacity: DC30V/3A;Contact resistance in normal condition: 100kΩ;Closed when activated;Suitable for DC or AC12V~48V;Active output: DC24V/1.5A Indicator Red,Input indicator,Flashes when polling,Illuminates in action,Output indicator,Illuminates in action Coding method Electronically coding Code range 1~255 Material and color of enclosure ABS; Porcelain white Weight About 147g (with base) Mounting hole distance 60mm Dimension (L×W×H) 86mm×38mm×86mm (with base) Product installation manual and video at fire alarm module
$17.90The TX7230 manufactured base on the requirement of EN 54 part 17, European Standard. In the event of short circuit on the detection loop the TX7230 Isolators either side of the loop will detect the problem and open circuit and isolates the faulty part of the loop, enabling other devises on the unaffected part of the loop to operate normally. The module will continue to monitor for the fault to be repaired, once the fault is cleared the isolator will automatically reinstate the effected part of the loop.
TCXH5415W wireless fire hydrant button is suitable for installation in public places. when manually confirming to start the fire pump, press the start button on the fire hydrant button, and the red light of the fire hydrant button is always on, which can send a start signal to the control panel through wireless communication technology and start the fire pump at the same time; After the fire pump has been started, the fire hydrant button answer light is always on, the fire hydrant button sends an answer signal to the control panel through wireless communication technology, and the fire hydrant button enters the state of waiting for the control panel to reset. The control panel can display the coded information of hydrant button and make sound. Technical Data All data is supplied subject to change without notice. Specifications are typical at 24V, 25℃ and 50% RH unless otherwise stated. Battery CR17450 Rated Operating Voltage 3V Operating current monitoring current≤15uA , alarm current≤10mA Coding method automatically assigned when networking Radio frequency transmit power<20dBm Communication distance ≤500m Communication method 470MHz FSK coded bidirectional Operating environment temperature 10℃~+55℃ relative humidity ≤95% Dimension 96mm*95mm*50mm Weight 190g The 470MHz wireless communication technology is adopted, and no embedded wiring is needed, so the engineering installation is convenient and quick; With battery low voltage detection function, it can reflect the battery power situation in time; The microprocessor is used to realize signal processing, and the digital signal is used to communicate with the control panel, which works stable and reliably, and has a good ability to suppress electromagnetic interference.
$26.50Residual Current Transformer TC-DH01B-J325 Through-line aperture: 325 × 60mm main circuit rated operating current: less than 1000A Dimensions: 445mm × 220mm × 60mm Connected to the monitoring device JB-DH-TC5600 with a non-polar two buses, while achieving communication and power supply functions The address code is electronically encoded and can be written in advance by the electronic encoder. The engineering debugging is simple and reliable The microprocessor monitors the operation and transmits the status of the module to the monitoring device in both normal and alarm modes Wire system: non-polar connection to the signal bus of the monitoring device Residual current detector Specification: 1. Operating Voltage: Pulse voltage of circuit loop: Loop 24V Available range: 16V~30V 2. Operating current: Standby current≤0.4mA Alarming current≤0.7mA 3. Rated alarming current: 200mA~1000mA, step-size 1mA 4. Encoding mode: electrical addressable mode. It takes one site on the loop. And an addressable code could be any in the range of 1~255. 5. Cabling: connecting with the monitoring devices through signal nonpolar two-line loop. 6. Aperture of wires: 325mm×60mm 7. Rated operating current of main loop: less than 1000A. 8. Rated frequency of wires: 50Hz/60Hz 9. Ambient environment: Temperature: -10℃~+55℃ Relative humidity≤95%, non-condensing 10. Dimension: 445mm×220mm×60mm 11. Enclosure material: ABS plastic 12. Ingress Protection Rating: IP30 13. Weight: about 8kg
$120.00EN54-7 Compliance Commercial Fire Alarm System. Using microprocessor technology with memory capacity up to 10 events The TX7100 Intelligent Addressable Optical Smoke Detector is the ideal device for most applications,due to its spiffing linear response to a wide variety of different types of smoke patterns. The unitmanufactured the sensitivity requirement of EN 54 part 7, European Standard. The unit is aesthetically pleasing with unobtrusive design that will complement modern building designs. The unit incorporates an intelligent processor that provides Algorithm map, inbuilt A/D converter, Drift compensation, and Self-Diagnosis and History log.