Intelligent Fire Alarm control panel LPCB fire controller 1 Loop 255points (it is also available for 2/3/4 loops). Color menu display Intelligent bus control mode; max 255 addressable points per loop, max 4 loops, max 48 zones Loop card type design:1-4 loop card can be seledted Glass fuse per loop Black box function Independent controlling password for the specially needed gas recharging units Self-design loop protocol Wall-mounted structure, compact and exquisite Akzo outer coating;anti-corrosion Language:English Approvals:LPCB(EN54-2/4) CE TECHNICAL SPECIFICATIONS Volate AC230V(50HZ), Voltage range: +10%--15% Current 1A Outputs Fire output .Fault output .24V power output .Loop output Capacity 1020/4 loops addressable points LCD screen size 7-inch color LCD screen Standby bettery 12V/12AH sealed lead acid battery*2 Dimension(L*W*H) 420mm×140mm×560mm Operating environment Temperature:-5℃-+50℃: Relative Humidity:≤95%non- condensing Communication interface RS485、CAN、USB DETAILS The control panel is mounted on the wall through 4 mounting holes, the dimensions of the mounting holes are shown in the picture. The right side of the control panel has 8 wiring holes, which are easy for wiring between the control panel and field devices. There are also 5 knock holes at the top, if the holes on the right side are not enough. Product installation manual and at alarm system
$800.00▪ The non-polar two buses are connected to the monitoring device to realize the communication and power supply functions at the same time. ▪ The address code is electronical, which can be written in advance by the electronic encoder. The engineering debugging is simple and reliable, which can also be set directly on the machine ▪ The microprocessor monitors the operation and transmits the status of the module to the monitoring device in both normal and alarm modes. ▪ Wire system: Non-polar connection to the signal bus of the monitoring device ▪ Line rated frequency: 50Hz/60Hz ▪ Dimensions: 92mm × 59mm × 110mm How to use the combined electric fire monitor detector? Each combined electric fire monitor detector is installed in one power distribution box. It has 8 channels and can accept input of residual current detection or high temperature detection signal. The residual current detectos' outlet loops and temperatures detectors' outlet loops will be funneled into the combined electric fire monitor detector. Then it connects to addressable electric fire monitor panel TC-5600. From the TC-5600, you can set the residual current alarm value. What can the combined electric fire detector do? How to wire and encode it?
$45.00Bus communication 1 loop or 2 loops electric fire monitor controller. This monitoring panel should work with DH12A, DH01B and DH230 electrical fire detectors to form an electrical fire monitoring system. Each detector has its own independent coded address and alarm information is reported to the control panel. At the same time, each channel of the bus device is disconnected or short-circuited, and the communication fault of the device is reported to the host JB-DH-TC5600 Electrical Fire Monitoring Equipment. Video guidance to set up the electric fire monitor system Features and specifications: Large screen LCD screen, various alarms, faults, status and other information are displayed. Residual current detector, temperature sensor alarm value has wide range adjustable, wide adaptability The detector is electronically coded by easy and convenient installation The function of interconnecting with our fire alarm system Maximum 2 loops with 255 electrical fire detectors per loop bus The casing meets the requirements of IP30 strictly, and all gaps and vents are no more than 2.5mm Controller dimensions (L × W × H): 360mm × 130mm × 480mm Working environment: -10°C~50°C, humidity<=95% Power: 50Hz, AC220V+10%-15% backup battery: 24V/3.3AH Weight: 8kg Executive standard: GB4717-2005
$310.00Fire alarm relay output Fault relay output IR2 EXdIICT6 Product function and composition A705/IR2 can be applied to the need to monitor the implementation of the fire place, quickly found that the fire may cause the burning flame, issued in a timely manner Fire alarm. A705/IR2 is converted to electrical signal by two infrared pyroelectric sensors which work in different bands. Signal input industrial computing chip for comparison, operation and processing, with the detecter&anysafe II Ir dedicated intelligent control software, you can Send out a fire alarm in time. A705/IR2 uses the aluminum die-casting flameproof shell, has good protective properties and explosion-proof, corrosion resistance, aging resistance, can work for a long time In the indoor, outdoor and all kinds of special industrial places. Sensor sharp probe AE-S708/4 and AE-S708/5 infrared pyroelectric sensor Optical window :white gems (Al2O3) housing L material: aluminum alloy L molding process: Die Casting L coating process: surface electrostatic powder coating, internal metal passivation treatment. The weight is less than 1kg Explosion proof and protection l anti explosion: EXd II CT6 L protection: IP66 Working parameters Project specifications or status Minimum standard of power supply 18VDC (can be customized 12VDC) 30VDC 24VDC The current monitoring status of less than 15mA, the alarm state is less than or equal to 35mA Pre heating time 60s Fire alarm when the monitored area is found in the fire, the detector into the fire state; Fire alarm output relay action, red fire indicator light; Fault alarm When the sensor, power supply and other anomalies are found, the detector enters into the fault alarm state; Fault output relay action, yellow fault indicator light; When the fire and failure occurred at the same time, the priority of the fire; Multistage adjustable alarm threshold (by bar set) Monitor the state each time the green light flashes to indicate the alarm threshold Alarm delay 0-30S adjustable (factory set to 0S) A combination model of hardware compensation and intelligent software compensation for drift compensation sensor Can effectively compensate for the temperature, environmental changes and components of the long-term work of drift Interference source suppression can effectively suppress the impact of non flame interference sources, such as the sun (direct and reflection), commonly used artificial light source, background Radiation source, heat moving objects, electric welding, etc. Indicator light L monitor status: green light L fire status: red light always light L fault status: yellow light is always bright output L fire alarm relay, alarm action, output contact 3A@125VAC 3A@30VDC L fault relay, fault time action, output contact 3A@125VAC 3A@30VDC L serial communication interface Environmental parameter Project specifications Operating temperature of -10 degrees C - +55 C or -40 -+70 Working humidity is less than or equal to 95%HR, no condensation Storage temperature -40 C +85 FLJD and FLJK Connection detector fault output contact, when the probe Failure or power supply failure When the contact is broken FRJD and FRJK connection detector fire alarm output contacts, when the When the alarm is measured, the contact is closed. 24V external power supply positive electrode GND external power supply negative electrode
$269.00TC5105 fire alarm and gas fire-extinguish Product Description Gas fire-extinguishing system is mainly used in environments that are not suitable for setting water fire extinguishing system and other fire extinguishing systems, such as computer room, important library archives, mobile communication base station (room), UPS room, battery room, general diesel generator room, etc. * Color menu display * Max 4 fire protection zones and 1 Fire Alarm loop * Max 6 direct control points * Networking function * Built-in printer * Wall-mounted structure ,compact and exquisite * Connection with field devices through loop control * The system is a combination of alarm, linkage and gas fire-extinguishing * Devices can be connected include smoke detector, heat detector, flame detector, MCP, emergency start/abort button, sounder strobe, gas spray indicator, auto/manual switch module and I/O module Main power supply: AC220V(3A), Voltage range: +10%~-15% Battery: DC24V (10A), 12V/12AH sealed acid battery *2 LCD screen: 4 inch color LCD screen, resolution:480*272 Capacity: 255~510 points /1~2 loops /2~4 zones Operating environment: Temperature: 0~+40°C, relative humidity<=95% non-condensing Dimension: 385mm*134mm*510mm Communication interface: RS485, CAN, USB L, N, PE: AC 220V terminals and AC grounding terminals. L+, L-: non polarized alarm loop signal bus system terminals. Qn+, Qn-: non-polarized gas loop signal bus system interface, n: gas zone, No.1~4.NO, CM, NC: fire alarm volt-free output interface (NO: volt-free open junction, CM: volt-free sharing junction, NC: volt-free closed junction). SG+, SG-: sounder strobe control output terminals (volt control point, active output DC24V, output DC24V stopped after manually stopped or reset). A2, B2: RS485 terminals connecting figure display in fire protection control room, A2 for A point of485, B2 for B point of485. Al, BI: RS485 terminals, Al for A point of485, BI for B point of 485 (optional). Qn, Gn, Hn: direct control interface of threc-wire system, n for loop No. for three-wire system,No. 1-6. CH, CL: polarized Can bus system of control panel networking. JP2: pin set at the peripheral networking terminal on loop mainboard. Short cut piece jumps to ON when the panel is connected to peripheral network terminal,24V, GND: linkage power output terminals. Encode corresponding detectors and modules of gas fire-extinguishing.
$580.00JB-TB-TC5126W Wireless Fire Alarm Control Panel's typical configuration includes: main control panel, loop control panel, direct control panel, power supply, etc. The control panel is small in size, convenient to install and simple to operate, and is widely used in fire fighting engineering. The fire alarm control system can be widely used in small-scale fire fighting projects such as high-grade office buildings, residential quarters, department stores, gymnasiums, libraries, supermarkets, hotels. Technical Data: All data is supplied subject to change without notice. Specifications are typical at 24V, 25℃ and 50% RH unless otherwise stated. Main Power Supply AC220V(3.5A), range:+10%~-15% Battery lead-acid battery 12V/3.3Ah*2 Capacity 2 wireless loops 64 points/loop 40 network segments Radio frequency transmit power<20dBm Frequency band 470MHz Communication distance ≤700m Operating environment temperature 10℃~+55℃ relative humidity ≤95% Dimension 360mm*130mm *480mm With the new generation of high-speed processors, compared with the traditional technology, the data processing speed is faster and the data storage capacity is larger. Networking with other fire alarm control panel through CAN System operation history recording function: fire alarm history, linkage history, fault history and other history each have a capacity of 1000.
$700.00 $610.00Product Description Conversion Between manual operation mode and automatic operation mode Installed at the entrance of the protected area In manual state,systems will not linkage In automatic state,systems will linkage Compatible with JB-QB-QTC5015 Gas Fire-Extinguishing Control Panel Operating voltage: Signal bus voltage: bus 24V, range 16V~28V Operating current: <=1mA Coding method: Electronic coding, coding range can be set between 39~40 Weight: about 110g Operating environment: Temperature 0~+40°C, relative humidity<=95% non-condensing Dimension: 86mm*86mm*38mm Mounting hole distance: 60mm Material and color of enclosure: ABS, Milky white
$18.00The TX7300 Addressable Sounder Strobe is alarm warning device used to notify persons in the vicinity of the occurrence fire emergency in order the person to take appropriate measures. The unit adopt multi-application device starting from the types, parameters and wiring layout in single unit. The TX7300 can change into different alarm warning types such as sounder-strobe type, sounder type or strobe type using programming tool. In addition, parameters can be configured according to the requirement which include alarm tone from 17 different tones, single address or dual address mode and also setting of power mode to low current consumption in a simple programming.
Analogue sensor and digital addressing Provide real time algorithm to the control panel 360 degree visual indicator The TX7110 Intelligent Fixed and Rate of Rise Heat Detector is reliable for application in places where may have high dust level or smoky environments, making a normal smoke detector undesirable. The unit manufactured base on the sensitivity requirement of EN 54 part 5, European Standard. The unit is aesthetically pleasing with unobtrusive design that will complement modern building designs. The unit incorporates an intelligent processor that provides inbuilt A/D converter, and Self-Diagnosis and History log.
TC-DH01B-30 should be used with JB-DH-TC5600 to builds up electrical fire monitoring system. The detector can realize the function of leakage test, temperature test and output controlling by connecting with JB-DH-TC5600 electrical fire monitoring. It can also connect with many other kinds of residual current transformers to realize stable and reliable operation. Electrical fire monitoring system can effectively prevent electrical fire and reduce losses. How to wire and encode the residual current detector? Watch video guidance at Features: 1. Connect with monitoring devices through nonpolar two-line loop to realize the function of communication and power supply. 2. The addressable code is electrical code, which can be programmed by electrical programmer. It is convenient and reliable for engineering commission. 3. The operating situation is monitored by the microprocessor. The microproccessor will transmit the mode status of normality or alarming to monitoring devices. Specification: 1. Operationg Voltage: Pulse voltage of circuit loop : loop 24V, available range 16~30V 2. Operating current: standby current <=0.4mA alarm current <=0.7mA 3. Rated alarm ing current: 200mA ~1000mA step size 1mA 4. Encoding mode: electrical addressable mode. It takes one site on the loop. And an addressable code could be any in the range of 1~255. 5. Cabling: connecting with the monitoring devices through signal nonpolar two line loop. 6. Through-line aperture: 32.5mm; 7. main circuit rated working current: less than 100A 8. Dimensions: 122mm × 102mm × 45mm 9. It has LED indicators of working, alarm and fault 10. Workding environment: Temperature: -10°C ~+55°C Relative humidity≤95%(non-condensing) 11. Enclosuer material:ABS plastic 12. Ingress Protection Rating: IP30 Execution standard: GB 14287.2-2014
$24.00TCBM5023 addressable fire alarm system programmer for TC-5109 ▪ Contact-type encoding method ▪ Simplify encoding procedure, shorten encoding time, and reduce work intensity ▪ Complete encoding within a second ▪ Greatly improve the efficiency of the engineering commissioning ▪ Manual structure, compact appearance ▪ LCD and English display ▪ Battery management function Technical Specifications Power supply 1.5V/AA battery *2 Operating current ≤40mA Standby current ≤2mA (4mA when the backlight is on) Operating Environment Temperature: -10°C~+50°C,Relative Humidity: ≤95%, non-condensing Dimension (L×W×H):60mm×29mm×155mm Product installation manual and video at fire alarm
$58.00JTY-GM-TC5401W wireless photoelectric smoke detector is an intelligent industrial fire detector based on the principle of transmitting and receiving high- precision infrared tubes, which can be used with the wireless fire alarm control panel and smart home platform APP The detector uses 470MHz wireless transceiver technology to process data with a highly integrated micro-processing chip. It has the characteristics of high sensitivity, long transmission distance and low power consumption. Technical Data: All data is supplied subject to change without notice. Specifications are typical at 24V, 25℃ and 50% RH unless otherwise stated. Battery CR17450 3V Operating current monitoring current≤8uA , alarm current≤18mA Coding method: automatically assigned when networking Radio frequency transmit power<20dBm Frequency band 470MHz Communication distance ≤500m Communication method 470MHz FSK coded bidirectional Protection area 20~30m2 Operating environment temperature 10℃~+55℃ relative humidity ≤95% Dimension 100mm*55mm(with base) Weight 118g accurately and quickly detect the change of smoke concentration in the environment, accurately and timely determine the fire and give an alarm advanced wireless communication technology, signal transmission can be completed without wiring, and engineering installation is simple and convenient It has the function of battery low voltage detection, and reminds the user to replace the battery when it is insufficient to maintain the normal operation of the detector.
$22.50TC-L5719 Gas Extinguishing Indicator generally installed outside the gas extinguishing spraying area. When the gas extinguishing is carried out, the gas spraying indicator lights up, showing "Do not enter after deflation" to prevent people from entering by mistake and causing injuries. Non-polarized bus two-wire,ultra-low power consumption design,no need of DC 24V power supply Electronic code can be written in advance by encoder. BV copper conductor with cross-sectional area≥1.5mm2 shall be selected for DC 24V Operating Volate DC24V Operating Current ≤250mA Operating environment Temperature: -10~+55℃; relative humidity≤95%, non-condensing Coding method Electronic coding, coding range: can be set between 31~38 Dimension 86mm*86mm*38mm Mounting hole distance 60mm
$13.50LPCB Approved Intelligent smoke detector Addressable fire alarm system works with TC series addressable fire alarm system LPCB TC-5109 alarm panel fire fighting Infrared scattering principle Non-polarized two-wire Drift compensation and fault detecting function Reporting dirt fault Hotel, restaurant, warehouse, library, office building, teaching building, power plant and other places Approvals:LPCB(EN54-7) CE Technical Specifications Operating voltage Loop 24V(18.5V~26V) Operating current Standby current: ≤0.3mA;Alarm current: ≤0.8mA Operating Environment Temperature: -10°C~+55°C,Relative Humidity: ≤95%, non-condensing Indicator Red,Flashes when polling,Illuminates in alarm Ingress protection rating IP23 Material and color of enclosure ABS; Milky white Coding method Electronically coding Code range 1~255 Weight About 110g Mounting hole distance 60mm Dimension 100mm×51mm (with base) Product installation manual and video at smoke detector
$16.80Two-line loop of electrical fire monitoring equipment, non-polarized. TC-DH01B-50 with specification as below: Through-line aperture 50.5mm main circuit rated working current: less than 250A Dimensions: 150mm × 102mm × 45mm It has three led indicators works as below: Running indicator: Green. It flashes when the communication of detector and control panel is working normally. Leakage alarm: Red. It goes out when the leakage tube is normal. It lights steadily when the leakage tube alarms. Leakage fault: Yellow. It goes out when the leakage tube is normal. It flashes when the leakage tube sensor is in trouble. Parameter setup: The encoding mode of this detector is electrical program which is convenient and efficient. Connect TCBM5023 electrical programmer with loop terminals of detector(non-polarized).Then the detector can read address and be programmed with addressable code. Please refer to Hand Held Programmer Installationand Operation Manual for details.
$32.00TCSB5406W wireless manual call point is suitable for installation in public places, factories and other environments. When a fire is manually confirmed, press the button, and the red light of the MCP is always on, so that an alarm signal can be sent to the control panel through wireless communication technology. When the control panel responds to the alarm signal, the MCP enters a state of waiting for the control panel to reset, and the control panel displays the coded information of the MCP and gives an alarm sound. You can set mobile phone for the fire alarm, watch video at https://www.youtube.com/shorts/_OUV9_ZrYX4 Technical Data All data is supplied subject to change without notice. Specifications are typical at 24V, 25℃ and 50% RH unless otherwise stated. Battery CR17450 3V Voltage range 2.7~3.3V Operating current monitoring current≤10uA , alarm current≤19mA Coding method automatically assigned when networking Radio frequency transmit power<20dBm Frequency band 470MHz Communication distance ≤500m Operating environment temperature 10℃~+55℃ relative humidity ≤95% Dimension 95mm*96mm*50mm Weight 190g Push-type structure design is adopted, and special tools are required to reset after pressing MCP; Using 470MHz wireless communication technology, there is no need to embed wiring, and the engineering installation is convenient and fast; with battery low voltage detection function, which can reflect the battery power situation in time; Using microprocessor to realize signal processing, communicating with controller by digital signal, it works stably and reliably, and has good ability to suppress electromagnetic interference.
$22.50TX7201 Addressable Zone Monitor unit is an addressable interface module, which will integrate conventional detectors or conventional manual call points to addressable system. When any of the connected devices alarms are active, the unit can send the alarm message to fire alarm controller, which generates alarm signal and displays its address. The unit can match with the conventional optical smoke detector, conventional rate of rise and fixed temperature detector and conventional manual call point etc. It has the function of checking short or open circuit of the output connection, by the End of Line Resistor (EOLR). The fault massage includes open circuit, short circuit or any removal of the detectors.
TX7130 Conventional Reflective Beam Detector has built in Laser beam pointing and Digital guide display for real user friendly alignment method. The Laser beam pointing accurately point the exact location where to mount mirror and with additional digital guide display allows to monitor and guide on the actual light intensity between the mirror and detector which cannot be seen by our naked eye making it more easy and convenient in alignment commissioning. The TX7130 has four adjustable operational ranges of between 8 to 20, 20 to 40, 40 to 70 and 70 to 100 meters beside with three adjustable sensitivity setting ranges from 2.6dB, 3.8dB and 5.8dB to meet the specific environmental requirement. The TX7130 works on the principle of reflective infrared beam obscuration. Used in conjunction with a reflector, it will notify the fire alarm panel when the infrared beam is obscured by smoke. The TX7130 is ideal for use high ceiling and wide areas such as warehouses, large storages, shopping malls, leisure centers, exhibition halls, hotel lobbies, printing houses, garment factories, museums and prisons, as well as places where slight smoke particles or corrosive gas exist.