Fire alarm siren works with TC series addressable fire alarm system TC-5109 LPCB alarm panel. LPCB certified addressablel horn strobe flash and sounder Installed in public places A kind of audio and visual alarm device used to warn people in field when fire occurs Four wires:non-polarized signal two-wire, and non-polarized DC24V power two-wire Built-in microprocessor Self-diagnostic function Electronically coding Approvals:LPCB(EN54-3) CE Technical Specifications Operating voltage Loop: 24V (16V~28V);Power: DC24V (DC19V~DC28V) Standby current Loop: ≤0.2mA;Power: ≤0.5mA Active current Loop: ≤1.5mA;Power: ≤50mA Operating Environment Indoor (Non-residential);Temperature: -10°C~+50°C; Relative Humidity: ≤95%(40±2°C) Sound level 80dB~115dB (A weighted) Pitch shift periodic 3.5S~4.5S Basic flashing frequency 1Hz~2Hz Weight 200g Dimension (L×W×H) 115mm×55.3mm×140mm Product installation manual and video can be found at fire horn
$18.50Measuring Range of 0~100% LEL combustible gas leakage alarm. This detector can be wall-mounted and cabled easily (AC 220V-plug, DC 12V solenoid valve-plug). It is stable and don't need commission, with wide range ofenvironmental adoption. JT-TC521 independent detector is widely used in houses, hotels, apartments or other places that combustible gas may exist. This detector can monitor natural gas, liquefied petroleum gas and artificial gas. Features ● Equip with high-quality gas sensor, reliable and corresponding. ● The intelligent algorithm of the microprocessors can compensate for the drift of gas sensor. ● The precision temperature sensor is a supplement of the monitoring of the environment temperature, which completely eliminates false alarms. ● LEDs indicate the detector status of normal, alarm and fault. ● The shell of the detector use fire-resistant ABS engineering plastic, clean and generous. Technical Specifications 1) Operating power: AC 220V 2) Standby current: 6 mA 3) Alarming current: 7 mA 4) Ambient temperature: -10℃~+50℃ 5) Operating humidity: ≤95%RH 6) Sound level: >75dB 7) Pressure: 86kPa-106kPa 8) First stabilization period: 3 min 9) Expiration date of sensor: >5 years(in clean air) 10) Alarm threshold: methane: 8% LEL 11) Detecting gas: available for natural gas, artificial gas, liquefied petroleum gas and many other kinds of combustible gas. 12) Output contact: active contact, available for one-way pulse electromagnetic valve of DC 12V; the drive capability of electromagnetic valve: 1000 μF capacity discharge. 13) Wiring: ①White plug: Connecting DC 12V solenoid valve ②White terminal: Connecting AC 220V 14) Dimension: 120mm×86mm×48mm
$16.50Electrical fire monitoring system residual current detector. Built-in processor can receive the signal from transformer and handle those signal into two forms as normality and alarming, both of which will be transmitted to the electrical fire monitoring equipment. The microprocessor will transmit the mode status of normality or alarming to monitoring devices. How to use electric fire monitor equipment and how to install? Technical Features 1. Operating Voltage: Pulse voltage of circuit loop: Loop 24V Available range: 16V~30V 2. Operating current: Standby current≤0.4mA Alarming current≤0.7mA 3. Rated alarming current: 200mA~1000mA, step-size 1mA 4. Encoding mode: electrical addressable mode. It takes one site on the loop. And an addressable code could be any in the range of 1~255. 5. Cabling: connecting with the monitoring devices through signal nonpolar two-line loop. 6. Aperture of wires: 93mm 7. Rated operating current of main loop: less than 630A. 8. Rated frequency of wires: 50Hz/60Hz 9. Ambient environment: Temperature: -10℃~+55℃ Relative humidity≤95%, non-condensing 10. Dimension: 188mm × 145mm × 45mm 11. Enclosure material: ABS plastic 12. Ingress Protection Rating: IP30 13. Weight: about 1.3kg
$55.00TCSG5416W wireless sounder strobe is suitable for installation in public places, factories and other environments, and is used together with JB-TB- TC5126W wireless fire alarm control panel. When the control panel receives the fire alarm instructions from other fire alarm devices, the control panel starts the alarm through wireless signals, and the alarm sends out sound and light signals to achieve the purpose of audible and visual alarm. Technical Data All data is supplied subject to change without notice. Specifications are typical at 24V, 25℃ and 50% RH unless otherwise stated. Battery CR17450-2-080-02 Rated Operating Voltage DC3V Operating current monitoring current≤45uA , alarm current≤240mA Sound level 75dB~115dB Coding method automatically assigned when networking Radio frequency transmit power<20dBm Communication method 470MHz FSK coded bidirectional Communication distance ≤500m Operating environment temperature 10℃~+55℃ relative humidity ≤95% Dimension 101mm*137mm*43mm Weight 170g The 470MHz wireless communication technology is adopted, and no embedded wiring is needed, so the engineering installation is convenient and quick; With battery low voltage detection function, it can reflect the battery power situation in time; The microprocessor is used to realize signal processing, and the digital signal is used to communicate with the control panel, which works stabely and reliably, and has a good ability to suppress electromagnetic interference.
$38.00TCMK5265 Addressable I/O Module non-polarized two bus,ultra-low power consumption,no need to add DC24V power supply passive outputvv input and output have isolating loop to effectively filter out external interference 1.Fix the base with two tapping screws,and then connect loop to terminals(polarity-insensitive).After thebase is fixed firmly,rotate the bottom of detector and base clockwise,and then the detector will be fitted tothe base. 2.Wiring instructions:RVS twisted pair with cross-sectional area≥1.0mm2 should be selected for the secondbus of the detector,which should be laid through metal pipe or flame retardant pipe.The length of theconnecting wire should be limited to the single bus resistance≤20Q,otherwise the wire diameter should beincreased. Rated operating voltage Loop:24V(14V~28V); Operating current Monitoring current: ≤ 0.2mA start current: ≤ 0.5mA Operating Environment Temperature:-10℃~+55℃; Relative Humidity:≤95% non-condensing Input supervisory external loop Open circuit occurs when normally open terminal supervising externalloop (short circuit is an action signal), the module will send a fault signalto the control panel. Material and color ABS;Porcelain white Output supervisory external loop Short circuit or open circuit on the output loop occurs, the module will send a fault signal to the contaol panel Weight 147g Mounting hole distance 60mm Dimension(L×W×H) 86mm×38mm×86mm(with base)
$20.00Residual Current Electrical Fire Monitoring Detector TC-DH01B-J225 Through-line aperture: 225 × 56mm main circuit rated operating current: less than 630A Dimensions: 296mm × 166mm × 45mm Standard: GB14287.2-2014 "Electric Fire Monitoring Systems - Part 2: Residual Current Electric Fire Detectors” The Detector builds up an electrical fire monitoring system with our productions of JB-DH-TC5600 Electrical Fire Monitoring Equipment, TC-DH12A Combined Electrical Fire Monitoring Detector and TC-DH230 Combined Electrical Fire Monitoring Detector. The Detector can realize the function of leakage test, temperature test and output controlling by connecting with JB-DH-TC5600 Electrical Fire Monitoring Equipment through two-line loops. It can also connect with many other kinds of residual current transformers to realize stable and reliable operating. Electrical fire monitoring system can effectively prevent electrical fires and reduce losses. Technical Specifications: 1. Operating Voltage: Pulse voltage of circuit loop: Loop 24V Available range: 16V~30V 2. Operating current: Standby current≤0.4mA Alarming current≤0.7mA 3. Rated alarming current: 200mA~1000mA, step-size 1mA 4. Encoding mode: electrical addressable mode. It takes one site on the loop. And an addressable code could be any in the range of 1~255. 5. Cabling: connecting with the monitoring devices through signal nonpolar two-line loop. 6. Aperture of wires: 225mm×56mm 7. Rated operating current of main loop: less than 630A. 8. Rated frequency of wires: 50Hz/60Hz 9. Ambient environment: Temperature: -10℃~+55℃ Relative humidity≤95%, non-condensing 10. Dimension: 296mm×166mm×45mm 11. Enclosure material: ABS plastic 12. Ingress Protection Rating: IP30 13. Weight: about 3kg
$60.00Addressable fire alarm system TC-5109 compatible Single I/O Module LPCB intelligent Module Designed to connect with linkage devices of fire alarm controlpanel, such as exhaust valve, air valve, fire damper etc., and can receive feedback signal from device Non-polarized two-wire Active and passive output The input terminal can be in field set to normally open detecting wire or self-feedback mode, which can be connected with passive contact Approvals:LPCB(EN54-18) CE Technical Specifications Operating voltage Loop:24V (18.5V~26V);Power: DC24V (DC19V~DC28V) Standby current Loop: ≤0.2mA;Power: ≤2mA Starting current Loop: ≤2mA;Power: ≤22mA Operating Environment Temperature: -10°C~+55°C;Relative Humidity: ≤95%, non-condensing Output capacity Passive:Capacity: DC30V/3A;Contact resistance in normal condition: 100kΩ;Closed when activated;Suitable for DC or AC12V~48V;Active output: DC24V/1.5A Indicator Red,Input indicator,Flashes when polling,Illuminates in action,Output indicator,Illuminates in action Coding method Electronically coding Code range 1~255 Material and color of enclosure ABS; Porcelain white Weight About 147g (with base) Mounting hole distance 60mm Dimension (L×W×H) 86mm×38mm×86mm (with base) Product installation manual and video at fire alarm module
$17.90TCXH5415W wireless fire hydrant button is suitable for installation in public places. when manually confirming to start the fire pump, press the start button on the fire hydrant button, and the red light of the fire hydrant button is always on, which can send a start signal to the control panel through wireless communication technology and start the fire pump at the same time; After the fire pump has been started, the fire hydrant button answer light is always on, the fire hydrant button sends an answer signal to the control panel through wireless communication technology, and the fire hydrant button enters the state of waiting for the control panel to reset. The control panel can display the coded information of hydrant button and make sound. Technical Data All data is supplied subject to change without notice. Specifications are typical at 24V, 25℃ and 50% RH unless otherwise stated. Battery CR17450 Rated Operating Voltage 3V Operating current monitoring current≤15uA , alarm current≤10mA Coding method automatically assigned when networking Radio frequency transmit power<20dBm Communication distance ≤500m Communication method 470MHz FSK coded bidirectional Operating environment temperature 10℃~+55℃ relative humidity ≤95% Dimension 96mm*95mm*50mm Weight 190g The 470MHz wireless communication technology is adopted, and no embedded wiring is needed, so the engineering installation is convenient and quick; With battery low voltage detection function, it can reflect the battery power situation in time; The microprocessor is used to realize signal processing, and the digital signal is used to communicate with the control panel, which works stable and reliably, and has a good ability to suppress electromagnetic interference.
$26.50Residual Current Transformer TC-DH01B-J325 Through-line aperture: 325 × 60mm main circuit rated operating current: less than 1000A Dimensions: 445mm × 220mm × 60mm Connected to the monitoring device JB-DH-TC5600 with a non-polar two buses, while achieving communication and power supply functions The address code is electronically encoded and can be written in advance by the electronic encoder. The engineering debugging is simple and reliable The microprocessor monitors the operation and transmits the status of the module to the monitoring device in both normal and alarm modes Wire system: non-polar connection to the signal bus of the monitoring device Residual current detector Specification: 1. Operating Voltage: Pulse voltage of circuit loop: Loop 24V Available range: 16V~30V 2. Operating current: Standby current≤0.4mA Alarming current≤0.7mA 3. Rated alarming current: 200mA~1000mA, step-size 1mA 4. Encoding mode: electrical addressable mode. It takes one site on the loop. And an addressable code could be any in the range of 1~255. 5. Cabling: connecting with the monitoring devices through signal nonpolar two-line loop. 6. Aperture of wires: 325mm×60mm 7. Rated operating current of main loop: less than 1000A. 8. Rated frequency of wires: 50Hz/60Hz 9. Ambient environment: Temperature: -10℃~+55℃ Relative humidity≤95%, non-condensing 10. Dimension: 445mm×220mm×60mm 11. Enclosure material: ABS plastic 12. Ingress Protection Rating: IP30 13. Weight: about 8kg
$120.00TCSB5214H TC fire alarm system series LPCB approval addressable 2-wire bus type Voltage: Loop DC24V(16V-28V) Digital Manual Call Point (With Jack) (MCP) is installed in public places. The MCP contains a phone jack. And when there is a fire, pressing the frangible element on this MCP can send fire signal to Fire Alarm control panel. After receiving the signal, the control panel will show address information of the MCP and generate alarm sound. Insert the Fire Telephone handle into the phone jack, and then communicate the fire telephone panel. Features 1.Plug-in structure. Simple and convenient installation. Alarm by pressing, reset by a special key. 2.Pressing the frangible element and it can provide independent output contact through the MCP. And it can directly control other peripheral devices. 3.Microprocessor processes signal and digital signal communicates the Fire Alarm Control Panel. Stable and reliable work, good ability to inhibit electromagnetic interference. 4.Electronically addressed. The address can be modified in field. Easy and reliable for commissioning. Technical Specifications 1.Operating voltage Signal bus voltage: loop 24V 2.Operating current Standby current: ≤ 0.2mA Alarm current: ≤ 0.8mA 3.Type of initiating part: Reusable 4.0Initiating mode: Pressing the frangible element manually 5.Resuming mode: Manually resumed by a special key 6.Indicator Running/fire LED: Red. Flashes every 3s when polling. Illuminates after alarming. Fire telephone: Red. Flashes every 5s. 7.Programming mode Electronically addressed (address range: one address within 1~255). 8.Wiring Non-polarized signal two-wire 9.Operating environment Class: indoor Temperature: -10°C~+55°C Relative Humidity: ≤95%, non-condensing 10.Dimension Diameter: 90mm×90mm×42 mm (with base) 11.Material and color of enclosure: ABS; red 12.Weight: about 120g(with base) 13.Mounting hole distance: 60mm 14.Standard: GB 19880-2005 Call Point with Jack
$15.90Equipped a color LCD and a printer available for all information when alarms, errors or other operations occur. It finds that combustible gas leaks in industrial environment and daily living environment. When combustible gas alarm system detects that the concentration of combustible gas reaches the alarm value set by the alarm system, the combustible gas alarm will send out sound and light alarm signals to remind people to take safety measures such as evacuation, forced air exhaust and equipment shutdown. ▪ Color menu display ▪ Max 1 loop ▪ Networking Function ▪ Wall-mounted structure ,compact and exquisite ▪ Built-in printer ▪ Strong anti-interference capability Technical Specifications Mains supply: AC220V (3A),Voltage range: +10%~-15% Standby battery: 12V/7AH sealed lead acid battery *2 LCD screen size: 4.3-inch color LCD screen Operating Environment: Temperature: 0°C~+40°C;Relative Humidity: ≤95%, non-condensing Capacity: 255 addressable points Communication Interface: RS485、CAN、USB Dimension (L×W×H): 320mm×120mm×400mm
$390.00TCTXM5000-RS MODBUS-RTU CONVERTER is a protocol repeater for fire alarm system monitoring. This product adopts serial communication technology, through accurate data acquisition technology, to monitor, collect and analyze data in an all-round way. Through advanced serial port data transmission technology, the collected data will be sent to the end user. It can monitor the equipment in the fire alarm control panel in real time: alarm, start, stop, feedback, failure, shielding, and supervision and other parameters, the information of the fire alarm control panel can be inquired according to different partitions and addresses. It is easy to install and adopts RS485 serial communication technology to support long-distance wiring. Convenient debugging, configuration parameters can be debugged through the computer serial port, simple, convenient and fast. It is easy to debug and can monitor various parameters of the fire alarm system in real time. When there is information such as fire alarm or fault, the information can be uploaded to the user monitoring system through the serial port query to realize real-time monitoring and real-time processing.
$300.00TCMK5411W wireless input module is suitable for installation in public places, factories and other environments. When there is a fire alarm, the module will send an alarm signal to the control panel through wireless communication technology after receiving the input signal specified by the manufacturer, and the red light is always on. Technical Data All data is supplied subject to change without notice. Specifications are typical at 24V, 25℃ and 50% RH unless otherwise stated. Battery CR17450 Rated Operating Voltage 3V Operating current monitoring current≤13uA , alarm current≤20mA Coding method automatically assigned when networking Radio frequency transmit power<20dBm Communication method 470MHz FSK coded bidirectional Communication distance ≤500m Operating environment temperature 10℃~+55℃ relative humidity ≤95% Dimension 101mm*137mm*43mm Weight 160g The 470MHz wireless communication technology is adopted, and no embedded wiring is needed, so the engineering installation is convenient and quick; With battery low voltage detection function, it can reflect the battery power situation in time; The microprocessor is used to realize signal processing, and the digital signal is used to communicate with the control panel, which works stable and reliably, and has a good ability to suppress electromagnetic interference.
$25.50Addressable Fire Alarm Loop Isolator Module TCMK5210 Wiring type: Non-polar two bus Type: Isolator Action Current: 170mA/270mA Load Capcaity: Loop,24V,170mA/270mA (B, ZX2 short circuit) Mounting Hole Distance: 60mm Ingress Protection Rating: IP30 Specification: 86mm*86mm*40mm (with base) Approval: LPCB, CE, GOST
$18.00JT-TC518 Addressable Combustible Gas Detector of Measurement Range 0-100%LEL It adopts advanced semiconductor gas sensors using at room temperature and microprocessors in conjunction with precision temperature sensor, which can compensate for the drift of intelligent gas sensor. This detector can be wall-mounted and cabled easily. It is stable and don't need commission, with wide range of environmental adoption. JT-TC518 addressable detector is widely used in houses, hotels, apartments or other places that combustible gas may exist. This detector can monitor natural gas and other combustible gas containing methane. Features ● Equip with high-quality gas sensor, reliable and corresponding. ● The intelligent algorithm of the microprocessors can compensate for the drift of gas sensor. ● The precision temperature sensor is a supplement of the monitoring of the environment temperature, which completely eliminates false alarms. ● LEDs indicate the detector status of normal, alarm and fault. ● The shell of the detector use fire-resistant ABS engineering plastic, clean and generous. Technical Specifications 1) Operating power: DC 24V 2) Standby current: 21 mA 3) Alarming current: 28 mA 4) Ambient temperature: −10℃〜+50℃ 5) Operating humidity: ≤95%RH 6) Sound level: >75dB 7) Pressure: 86kPa-106kPa 8) First stabilization period: 3 min 9) Expiration time of sensor: >5 years(in clean air) 10) Alarming threshold: methane: 8% LEL 11) Detecting gas: available to detect natural gas and many other kinds of combustible gas containing methane. 12) Output contact: active contact, available for one-way pulse solenoid valve of DC 12V; the drive capability of solenoid valve: 1000 μF capacity discharge 13) Encoding mode: addressable 14) Wiring: ①White plug: Connecting DC 12V solenoid valve ②Black line: Connecting DC 24V ③White line: Connecting the loop of control panel 15) Dimension: 120mmX86mmX48mm
$20.00TCZS5273 Detector remote indicator light (Hereinafter referred to as remote indicator light)It ismainly used in the bus connection in fire alarm system, It can be used with fire alarm smoke detector,heatdetector and Combination Heat and Smoke Detector.When the installation position of on-site testing equipment is not convenient to ob-serve the alarm state,it can cooperate with the remote indicator light to lead its alarm state to the positioneasy to observe,prompting the field staff to pay attention,so as to better control the scene situation. TCZS 5273 Detector remote indicator features: 1.Two-wire connection with external equipment,convenient on-site wiring 2.Share the address with the matching detection equipment,specifically patrol the indicator light separate-ly,easy to observe the current state of the equipment; 3.Using microprocessor to realize signal processing,using digital signal to communicate with the controller,the work is stable and reliable,and has a good ability to restrain electromagnetic interference TCZS 5273 Detector remote indicator Specification Rated operating voltage DC 24V Working current Monitoring current ≤0.21mA;Starting current ≤0.4mA Operating Environment Class: Indoor atmospheric pressure: 86kPa ~ 106kPa Temperature: 0℃ ~ +50℃ Relative humidity ≤95%, no condensation Indicator green : The fitting equipment shines during inspection Red: the alarm of the matching product is duration bright Electronic encoding method, sharing the same bus coding point with the matching product, the coding range can be set arbitrarily between 1 and 255. Reset mode controller reset Boundary dimension 86mm×86mm Shell material and color ABS, white
$5.50NAJ2214 Addressable Fire Extension Telephone handle works with TCSB5214H or same brand telephone jack It is a bus communication device special for fire protection system. The extension can transmit and receive signals with a Fire Telephone control panel. It is suitable for hotels, restaurants, office buildings, teach buildings, banks, warehouses, libraries, computer rooms and switching rooms. In traditional fire management, some information is managed in the form of paper files. Not only is the data record not comprehensive enough, but also it is difficult to consult and manage because data management is not applied. Tiancheng home safety all-wireless products are combined with the cloud platform, which can fully record and manage all the operation traces of equipment implementation. When the equipment fails, the system will automatically report it to the management party and the maintenance party, and the follow-up inspection and maintenance work will also be recorded in the whole process, so as to change the fire control work mode and further improve the fire control work management efficiency. Frequency Range: 300-3400Hz Operating Current: < 22mA Operating Environment: Temperature: - 10°C~+55°C; Relative Humidity: <95% Function: Matched with NAJ2213&NAJ2215 Dimension: 204 mmx 50mmX 38mm Mounting Hole Distance: 100mm Approval: CCCF
$13.50TC-ZJ402 The wireless signal extender is suitable for home wireless alarm system and industrial wireless alarm system. The repeater uses advanced wireless transceiver technology, built-in efficient anti-collision algorithm, and can set filtering rules, so that the repeater can work reliably in the system. At the same time, the repeater supports multiple groups of channels, so that the repeater can work in complex environments and in the presence of multiple hosts, realizing mutual non-interference, truly avoiding the collision of channels, and greatly improving the coverage of wireless networks. Technical Data All data is supplied subject to change without notice. Specifications are typical at 24V, 25℃ and 50% RH unless otherwise stated. Main power DC5V(Power Adapter) Standby power 3V/2400MAh Power consumption monitoring≤9W , alarm≤2.2W Operation indicator flash when normal Fault indicator on when standby power fails Communication indicator flash when forwarding info Wireless transmission power 19dBm Communication distance ≤500m Communication method 470MHz FSK coded bidirectional Operating environment temperature 10℃~+55℃ relative humidity ≤95% Dimension 130mm in diameter H:48mm Avoid excessive humidity in repeater installation position To ensure the long-term reliability and accuracy of the repeater, the wireless performance should be checked regularly. The free warranty period of this repeater is one year, with lifetime maintenance.
$35.50