Fire alarm relay output Fault relay output IR2 EXdIICT6 Product function and composition A705/IR2 can be applied to the need to monitor the implementation of the fire place, quickly found that the fire may cause the burning flame, issued in a timely manner Fire alarm. A705/IR2 is converted to electrical signal by two infrared pyroelectric sensors which work in different bands. Signal input industrial computing chip for comparison, operation and processing, with the detecter&anysafe II Ir dedicated intelligent control software, you can Send out a fire alarm in time. A705/IR2 uses the aluminum die-casting flameproof shell, has good protective properties and explosion-proof, corrosion resistance, aging resistance, can work for a long time In the indoor, outdoor and all kinds of special industrial places. Sensor sharp probe AE-S708/4 and AE-S708/5 infrared pyroelectric sensor Optical window :white gems (Al2O3) housing L material: aluminum alloy L molding process: Die Casting L coating process: surface electrostatic powder coating, internal metal passivation treatment. The weight is less than 1kg Explosion proof and protection l anti explosion: EXd II CT6 L protection: IP66 Working parameters Project specifications or status Minimum standard of power supply 18VDC (can be customized 12VDC) 30VDC 24VDC The current monitoring status of less than 15mA, the alarm state is less than or equal to 35mA Pre heating time 60s Fire alarm when the monitored area is found in the fire, the detector into the fire state; Fire alarm output relay action, red fire indicator light; Fault alarm When the sensor, power supply and other anomalies are found, the detector enters into the fault alarm state; Fault output relay action, yellow fault indicator light; When the fire and failure occurred at the same time, the priority of the fire; Multistage adjustable alarm threshold (by bar set) Monitor the state each time the green light flashes to indicate the alarm threshold Alarm delay 0-30S adjustable (factory set to 0S) A combination model of hardware compensation and intelligent software compensation for drift compensation sensor Can effectively compensate for the temperature, environmental changes and components of the long-term work of drift Interference source suppression can effectively suppress the impact of non flame interference sources, such as the sun (direct and reflection), commonly used artificial light source, background Radiation source, heat moving objects, electric welding, etc. Indicator light L monitor status: green light L fire status: red light always light L fault status: yellow light is always bright output L fire alarm relay, alarm action, output contact 3A@125VAC 3A@30VDC L fault relay, fault time action, output contact 3A@125VAC 3A@30VDC L serial communication interface Environmental parameter Project specifications Operating temperature of -10 degrees C - +55 C or -40 -+70 Working humidity is less than or equal to 95%HR, no condensation Storage temperature -40 C +85 FLJD and FLJK Connection detector fault output contact, when the probe Failure or power supply failure When the contact is broken FRJD and FRJK connection detector fire alarm output contacts, when the When the alarm is measured, the contact is closed. 24V external power supply positive electrode GND external power supply negative electrode