FW6000 Intelligent Fire Alarm Control Panel (FACP) is the new-generation fire alarm control unit designed for application in small and medium projects. It is wall-mounted type and has the advantages of powerful function, high reliability and flexible configuration. The panel is equipped with a LCD monitor to display all the information on fire alarms, faults and various operations, which can be printed out by the built-in printer. FW6000 is a one-loop control panel with maximum 240 points, which can work together with all FW 3 series field devices. Features: 1. This FACP uses two-wire bus system to control up to 240 addressable devices. 2. Wall mount design makes it easy to use and operate. 3. The FACP is composed of a main control module, a driver board and a communication board. 4. This FACP is compatible with the complete range of the FW series fire alarm devices like intelligent detectors, manual call point, input module, I/O module etc. 5. This FACP adopts windows-based operation menus, which are convenient and easily understood. 6. All the system functions can be realized just by simple operation to select the corresponding numbers or move the cursor. 7. The fire alarm sent out by this FACP is not only visible & audible, it can also be displayed on the LCD screen and be printed out by the built-in printer simultaneously, meanwhile, it can be recorded in the history log as well. Specification: 1. Primary AC Power supply: 220VAC 50/60Hz 2. Main supply output voltage (VDC): 27VDC & 32VDC 3. Mainy supply output current: 2.5A at 27VDC and 3A at 32VDC 4. Minimum battery size: 2*12V required 4Ah 5. Battery charging voltage (VDC): 27VDC 6. Battery charging current: 700mA 7. COM-SG connector voltage output: 1Amp @ 24VDC 8. DC24V connector voltage output: 1Amp @ 24VDC 9. COM-SG End of Line resistor (Ohms): 10K 10. COM-HJ contacts capacity: 2Amp @ 24VDC 11. COM-HJ End of Line Resistor (Ohms):10K 12. Computer Interface: USB 13. Display: Graphical LCD 128*64 14. Operating Humidity Range: 10% to 93% relative humidity, Non-condensing. 15. Operating Temperature Range: -10C to 50C 16. FACP Dimension (L*W*D): 330mm*120mm*400mm 17. FACP Neight weight: 7.8kg
$461.00Standard configuration of 2 loops addressable fire alarm control panel FW9000. ETL approval intelligent fire alarm control panel with good performance, flexible configuration and easy operation. Check information of alarm, fault and other operations is displayed by big LCD screen and can be printed by its built-in printer. The control panel supports 484 points two loops. If change installation, it can be extended to 64 loops. It can work with FW brand all types smoke detector, heat detector, manual call point, sounder strobes, modules and fireman's control panels to realize automatic fire alarm and control. Features: 1. The fire alarm panel has 2 loops in standard configuration and one loop can access 242 points. (FW devices). If the installation mode is changed, the extended loop can be extended to 64 loops and connected to 15488 detectors. 2. The panel has 6 sets of direct start buttons, which correspond to 6 sets of DC24V output and 6 sets of feedback access contacts, and 24 sets of addressable start buttons. 3. The panel is equipped with two DC12V battery backup to ensure the system can operate normally without AC power supply. 4. The panel have one RS-232 interface for PC panel configuration tool. It has two RS485 communication port for other external device. 5. The panel is connected to the computer through RS232, and the loop information and linkage information can equipment. 6. The panel has micro printer and can automatically print out fire alarm information, fault information etc. Specification: 1. Primary AC power supply: 220VAC 50/60Hz 2. Main supply output voltage (VDC): 27VDC &32VDC 3. Main supply output current: 2.5A at 27VDC, 3A at 32VDC 4. Minimum battery size 2*12V, DC12V/7Ah 5. Battery charging voltage (VDC): 27VDC 6. Battery charging current: 700mA 7. Sounder connector voltage output: 1Amp at 24VDC 8. DC24V connector voltage output: 1Amp at 24VDC 9. Fire feedback input end line resistor (Ohms): 10K 10. Fire feedback input contacts capacity: 2Amp at 24VDC 11. Printer: Built-in microwave printer 12. Computer interface: USB & RS232 13. Display: Graphical LCD 320*240 14. Operating humidity Range: 10%-93% relative humidity non-condensing. 15. Operating temperature: -10 to 50C 16. FACP dimension (L*W*D): 470mm*130mm*420mm 17. FACP net weight: 16.8kg
$568.004-zones conventional fire alarm fire automatic fighting system. Extinguishant Control Panel CM1004 Technical specification Mains supply 90 to 270VAC, 50Hz/60Hz Mains supply fuse 3Amp ( F3AL250V) Replace only with similar type Power supply rating 3Amps total including battery charge 28V +/- 2V Maximum ripple voltage ≤200 millivolts Battery type Two 12 Volt sealed lead acid in series. 7Ah maximum Battery charge voltage 27.6VDC nominal Battery charge current 0.7Amaximum Current draw in mains fail condition 0.095Amps With buzzer sounding Current draw in second stage alarm 0.235Amps Two zones in fire(470 ohm in circuit) Current draw in post discharge condition 0.310Amps solenoid outputs active Maximum current draw from batteries 3Amps With main power disconnected NAC outputs(sounder & bell circuit) 26 to 28V DC Fused at 500mAwith electronic fuse 1.2Amp total load over all circuits Fault relay contact rating 2A/30VDC maximum for each Volt free changeover contact Fire relay contact rating 2A/30VDC maximum for each Volt free changeover contact First stage contact rating 2A/30VDC maximum for each Volt free changeover contact Second stage contact rating 2A/30VDC maximum for each Volt free changeover contact Extract contact rating 2A/30VDC maximum for each Volt free changeover contact Zone quiescent current 4mA maximum Terminal capacity 0.5mm 2 to 2.5mm 2 solid or stranded wire Number of detectors per zone ≤30 PCS conventional detectors Number of sounders per circuit Dependent on type and current consumption Detection circuit end of line 4K7±5% 1/2 Watt resistor 3K-5.6K 1/2W Monitored input end of line 4K7±5% 1/2 Watt resistor 3K-5.6K 1/2W Sounder circuit end of line 10K±5% 1/2 Watt resistor 6.8K-20K 1/2W Extinguishant output end of line 10K±5% 1/2 Watt resistor 6.8K-20K 1/2W No. of detection circuits Four 21 to 28V DC No. of sounder circuits Four 21 to 28V DC Extinguishant release output 21V to 28V DC. Maximum load 2Amp Extinguishant release delay time Adjustable 0 to 75 seconds 5 second steps SIL,AL, FLT, RST inputs Switched – min resistance 0 ohms, max 1k ohms Detector alarm threshold 270 ohms to 1K ohms Call point alarm threshold 150 ohms to 1K ohms Short circuit threshold 0 ohms to 130 ohms Statusunit/Ancillary board connection Two wire RS485 connection with electronic fuse. Max. of 32 units-RS485 data cable Size 383mm W x 295mm H x 87mm D metal enclosure Weight 5kg
$169.00Alarm Control Panel is designed and manufactured to meet the requirement of BS EN54 Part 2&4. TX7004 comprise of a range of analogue addressable, microprocessor based fire alarm control equipment to offer flexibility in both design and operation. The System is modular concept for easy tailoring of system design, to meet the full requirements of the project. The TX7004 is designed to provide early warning fire detection, to quickly identify the location of fire and provide user definable text informing the occupants of the building of potential smoke spread. Simultaneously, the TX7004 will alert and evacuate the occupants, and control all necessary auxiliary command functions such as elevator control, air handling shut down, gas shut off & damper control, as per the cause and effects requirements configured though Command Builder Set-up The TX7004 modular construction panel, capable of supervising two monitored detection loops expandable up to four [4] loops on standalone basis. Each loop is capable to accommodate of 254 addressable devices of any combination with T&A protocols, namely intelligent sounder strobe TX7300 & intelligent sounder TX7320 complying with EN 54-3, rate of rise and fixed temperature heat detector TX7110 complying with EN 54-5, photoelectric smoke detector TX7100 complying with EN 54-7, intelligent manual call point TX7140 complying with EN 54-11, intelligent reflective beam detector (TX7130) complying with EN 54-12, input and output module TX7200, TX7210, TX7220 complying with EN54-18, and loop isolator TX7230 complying with EN 54-17. The T&A devices are fully loop powered to support saving cost of the cable. These systems incorporate a number of features to allow easy operation through a user-friendly menu. The TX7004 has a LCD touch screen and Keypad menus for alternative operation with large button access to operate the keypad control by fire brigade personnel providing total user-friendly interface for browsing and programming. Added the commission features such as colour coded loop mapping, dual address and device mismatch monitoring, one-man test, simplified command builder’s configuration that has proved to be highly rated by both commissioning and service engineers. The Control Panel has multiple built-in features. The loop card has built-in surge protection and the communication card interface support multiple interface protocol such as USB, Ethernet, CAN Bus, Serial, RS485, Fiber Optic in one singe card. The panel is Built-In Printer and 160 LED Zones Indicators. The panel provides variety of inputs and outputs interfaces and auxiliary such as Output to Sounder, F.P.E., Alarm and Fault output, Relays and Power Auxiliary. 1.2 Feature and Benefits • Compliance EN54-2 & N54-4 • Using advance microprocessor technology with Large memory capacity • Enhance user interface combining LCD Touch screen and keypad access • Support real time visual algorithm • Enhance false alarm prevention • Keypad and PC programming • Support Multiple interface protocol such as USB/Ethernet/Can Bus/Serial/RS485/Fiber Optic • Support Loop Powered devices for extra saving on cable cost • Built-In Printer and 160 LED Zones Indicators Commissioning Advantage • Auto Enrolling of Devices • Loop Mapping with colour coding status • Monitor device mismatch and dual address conflict • Command Builder to create requirements for fire event scenario • With Loop protection against power surge • One-man test with On/Off sounder • Programming Protection System Capacity • Up to 4 loop • Support 254 Devices/One loop (1,016 ideal) • Network up to 512 Node • Programmable Capacity • Zones up to 3000 • Sounders Groups 1-1000 • Other Groups 1001- 2000 • Built-in 160 LED Zones Indicator 1.4 Technical Specification • Compliance EN54-2 & 4 • Input Voltage 230VAC +10%-15%, 50Hz (120VAC, 60Hz, it is not applicable for EN54 & Not tested by LPCB) • Input Current Consumption 1A • PSU Output To CIE 21.5~28.5VDC • Batteries Maximum Charge Capacity: 2 x 12V / 28AH Maximum Charge Current: 1.2A I maxA: 0.93A I maxB: 2.53A Minimum Quiescent Current: 0.45A(Imin) Maximum Internal Resistance: 1.0Ω Rechargeable-Lead acid type battery • Recommended manufacturer and model of battery: PS-12280 12V28AH (Tested With CIE By LPCB) • Networking and Interfaces Panel to panel communication Can Bus [loop] Number of Panels 512 Interface Port USB, RS485 Serial, RS232 Serial, Ethernet • System Capacity Memory [Non-Volatile] 1000 Fire Events, 10,000 General Event Zones 3,000 programmable Total Group 3,000 programmable Sounder Group 1,000 programmable Common Group 2,000 programmable • Loop Specifications Protocol/Addressing T&A, Value range from 1 to 254 No. of Loop 4 Loop Protection Built-in 4kV Surge protection Power rating 16~24Vdc /120mA Cabling 1.0Km Max Length/2 x 1.5mm²solid core Fire resistance • Recommended Wiring (subject to local installation codes) ISST-SFR3/ 711c-(cl-5) Intelligent Safety & Security Technology Limited NoBurn XPS/ 682e/01 Ventcroft Limited FT30 SAFFIRE/ 1134j Draka UK Limited Context Plus/682a-(cl-3) Context Plus Ltd FP200 Gold LSOH/ 077k/01 Prysmian Cables & Systems Limited And all LPCB approved Fire cables Recommended Cable Length ≤1000m • Panel Input/outputs Programmable Relays 4 circuits: Normally Open/Close Programmable Input 1 Circuit: Current Limited 24Vdc (for future use) Programmable Auxiliary Power 19~28Vdc (Current Limited) Fixed Outputs (FPE/Sounder) 2 Circuits: 18~28Vdc (Current Limited) • Indicator 24 LED Status/ 160 Zone Indicators • Display 7” TFT Touch Screen • Keypad 5 Brigade buttons and Programming Keypad • Material / Color Flat sheet Metal / with outer glass door, Orange stripe • Dimension Lx W x H 530 mm x 490 mm x 135 mm • Weight 16.70 Kg • Temperature -5℃~+40℃ • Humidity 0 to 95% Relative Humidity, Non condensing
TCZS5273 Detector remote indicator light...