The conventional manual call point designed for conventional fire alarm system for reporting fire or emergency condition by its PUSH IN/PULL DOWN handle latches. One 470 ohm resistor is used on the PCB board between Zone+ and Zone- when the switch inside is closed. So the conventional manual call point is only used with conventional fire alarm control panel, it is forbidden to be used to other system. Conventional Manual Call Point, Operates by Advanced MCU Expert Algorithm Software. Fire alarm system category and installation instruction, datasheet, manual can be downloaded at fire alarm category Technical Specifications Ordering Information Individual(1 units) Dimensions (w x d x h millimetres) Weight 140x105x45 220g Dimension: 140mmX105mm Height: 45 mm Weight: 220 g Operating Temperature Range: -10°C to 50°C Operating Humidity Range: 10% to 93% Relative Humidity, Non condensing Latching Alarm: Reset by momentary power interruption Top Side Figure 1. Dimension of manual call point: Electrical Ratings System Voltage (nominal): 24 VDC (9V~ 28VDC) Standby Current: 60 μA @ 24VDC Alarm Current: 10~30 mA @ 24VDC call-point based upon our industry standard series housing, and features easy to install, push-fit wiring terminals. The unit can support either a 'Frangible Glass' element or a 'Non Frangible Plastic' element. Push in and Pull Down Call Point Can be reset by key Red colour Fire proof materials 470 Ohm Resistance Modern style Call Point
$9.50Outdoor sound flash light alarm. Suitable for patrol, fire, medical and so on. The alarm sound is strong, can obtain the visual and auditory shock effect with the low voltage and low power input. Product technical parameters 1. Working voltage: DC12-30V 2. Working current: ≤40mA 3. Working environment: -20℃ ~ +60℃ 4. Relative humidity: 0%~95%RH 5. Sound intensity: greater than or equal to 105dB (at a distance of one meter) 6. Product weight: 360g net weight 7. Flash intensity: greater than or equal to 1.2WS More details and complete fire alarm system category can be found at fire alarm
$24.00The conventional manual call point designed for conventional fire alarm system for reporting fire or emergency condition by its button latches. The call point has one 300 ohm resistor is used on the PCB board between Zone+ and Zone- or one relay contact (NO, COM, NC ) output when the button is pressed. INSTALLATION This manual should be left with the owner/user of this equipment. The call points should be installed in a position where they will not be subjected to mechanical stresses , and where the temperature is within the operating temperature range. Areas where there are , or are likely to be, aggressive substances should be avoided. Complete conventional fire alarm system manuals at manual call point SPECIFICATIONS Operating Voltage Range: 9~32VDC Volts Nominal Operating Resistance: 300Ω Relay Contact Ratings: 2A/30VDC Operating Humidity Range: 95% RH, Non-condensing Operating Temperature Range: -10°C to 50°C (14°F to 122°F) Dimensions: W89mm ,H93mm, D26mm Base Dimensions: W87mm ,H87mm, D31.5mm Weight: Net Weight 125g (with base) Colour/Case Material: Red/ ABS
$6.50Fire fighting gas system The Manual release is connected with Fire fighting panel. There are three buttons on the station, one is START button, and another one is STOP button. When the START button is pressed, you can press RESTORE button to restore the start button. Fire alarm and automatic fire fighting system component with instruction. Learn to install fire alarm system easy with video guidegas release fire fighting
$10.0024v conventional gas extinguisher and fire alarm system compatible gas release lamp 1. Comptaible with all the fire fighting panel 2. DC24V powered 3.LED light long life 4.Easy Installation Learn to install fire alarm system. Step by step instruction of fire alarm and fire automatic fighting system fire alarm fighting
$18.00Conventional fire alarm system remote LED flash lighting alarm The device is remote LED uses a state of-the-art designs. This LED is designed to be used with detectors. One 8mm LED provide local 360° visible alarm indication. They flash with the same as detector that be connected. Complete fire alarm system category and installation instruction manual can be downloaded at conventional fire alarm Features and Benefits Compatible with all the conventional fire alarm control panel 8mm Big Size LED Outside two holes provide 83mm(USA) Inner two holes provide 59mm(Europe) Wiring Terminals provided on the PCB board Technical Specifications Dimension: 102X86mm Height (including mounting base): 32 mm Weight: 50 g Operating Temperature Range: -10°C to 50°C Operating Humidity Range: 10% to 93% Relative Humidity, Non condensing Latching Alarm: Reset by momentary power interruption Electrical Ratings System Voltage (nominal): 3 VDC Alarm Current: 20 mA @ 24VDC
$5.00The fire alarm control panels (4 Zones, 8 Zones, and 16 Zones) provide all of the sophisticated features required of a leading edge conventional fire alarm system along with the simple operation and efficient installation methods demanded by both installers and building users. The panel can be flush or surface mounted and the generously sized metal back box allows ample space for rear or top cable entries. A comprehensive range of auxiliary devices is available to operate with the fire control panels including optical, ionization, photoelectric, and heat detectors. Each of the system components has been specifically designed to operate as part of the system. This provides assurance that the control panel, smoke detectors,interface devices and the ancillary components are all fully compatible with one another and that the full range of system functionality is supported by each device. Installation manual can be downloaded at alarm system support 1.1 Product features The panels have the following key features: 4, 8, or 16 conventional input zones. 2 notification appliance circuits (NAC, Sounder) with built-in synchronization forANSI 3.41and Gentex. The panel comes with a 3 amp power supply. Dedicated alarm and fault relays. 1 RS485 can be able to connect repeaters. Enclosure supports two 12V, 7Ah backup batteries. 1.2 Electrical specifications Primary AC 200 to 240VAC 50/60 Hz Standby current: 50mA@220VAC,Alarm current: 85mA@220VAC Power supply rating 3Amps @ 24VDC Maximum Battery Charging Current 0.98 Amps @ 26VDC Initiating Device Circuits 4 Zones Alarm Zone 1, 2, 3, & 4 Initiating Device Circuits 8 Zones Alarm Zone 1, 2, 3, 4, 5, 6, 7, & 8 Initiating Device Circuits 16 Zones Alarm Zone 1, 2, 3, 4, 5, 6, 7, 8,9,10,11,12,13,14,15, &16 Normal Initiating Operating Voltage 23VDC, Maximum 26VDC, regulated Short Circuit Initiating Current (per zone) 35mA Maximum Maximum Initiating Resistance (per zone) 10 ohms Initiating End-of-Line Resistor 4K7 ohms, 1/2W 5% Standby Detector Current (per zone) 4mA maximum Maximum Detector Count (per zone) 30 detectors Initiating Cabling Type 18AWG Twisted Shielded pair (14 – 18 AWG) Detector Base Impedance 430 ohms Notification Appliance Circuits(Sounder) 2 NACs, SpecialApplication Maximum NAC Current Rating 1Amp maximum per circuit NAC End-of-line Resistor 10K ohms 1/2W 5% FAULT Relay rating 2A& 30VAC, resistive Alarm(Auxiliary ) Relay rating 2A& 30VAC, resistive Enclosure Dimensions 353mm(L)×282mm(H)×101mm(W) Net Weight 3.1kg (Without batteries)
$139.00Conventional Maintenance Switch For Gas Extinguisher System This MAINTENANCE panel is a key switch, which disconnects actuation circuits in the system to prevent accidental discharge during maintenance operations. Two “LEDS” indicate “SYSTEM ARMED” and “SYSTEM INACTIVE”. When the key is inserted and turned towards “SYSTEM INACTIVE”, the red LED illuminates and the green LED indicating “SYSTEM ARMED” turns off. The key can only be removed in the “SYSTEM ARMED” position. This panel is also available with the key removable in both the “ARMED” and the “INACTIVE” positions. The information is silk-screened on a two-gang stainless plate. Switch rated at 5A 250VAC, the DC rating is 5A up to 30VDC. LEDS rated at 10mA each for a total current draw of 20mA. Video guidance to instruct how to install gas fire extinguishing fire alarm and fire automatic fighting system fire fighting
$19.00Fire floor display and repeat panels have the following key features: 16 conventional repeater display zones. Fire alarm output relay and 1 fault output relay . Fire alarm output with 24VDC. RS485 can be able to connect the other panel. You can download the complete fire alarm system category and installation instruction manual fire alarm installation Specifications Power supply: 16VDC to 30VDC Current of power: Standby current: ≤15mA, Alarm current: ≤75mA Relay contact capacity: 2A@24VDC Buzzer level: 80dB@1m. Protection level: IP55 Communication mode:RS485 (Wires: RVSP type,1.0MM2 to 2.0MM2) Dimension of enclosure: 200mm(W)*91mm(H)*45mm(D) Material of enclosure:ABS, White Weight: 350g. Hole of enter wires: 1/2 inch(12mm) Repeater status indication and button operation FIRE ALARM Status: When a fire alarm occurs, the corresponding zone red LED flashing and the internal buzzer sounds. When “Silence” button pushed, the alarm zone LED lights steady and the buzzer silenced. When another new fire alarm occurs, the new zone red LED flash and the buzzer sound again. In the fire alarm status, the fire alarm “FIRE OUT” relay active and output “NO, NC, C” relay contacts and 24vdc power output. FAULT Status: When a fault event occurs, the corresponding zone’s yellow LED flashing and the internal buzzer sounds. When “Silence” button pushed, the fault zone LED lights steady and the buzzer silenced. When another new fault event occurs, the new zone yellow LED flash and the buzzer sound again. In the fault alarm status, the fault alarm “FAULT OUT” relay active and output “NO, NC, C” relay contacts. Normal status: When fire alarm panel’s fire or fault event restored, the fire alarm panel would send commands to let the repeater to the Normal Status. RUN LED: The “RUN” LED would keep light steady when the power supply in normal status. COMM. LED: The “COMM.” LED would flash once about three to five seconds in normal communication status. SILENCE LED: In the fire or fault alarm status, press the “Silence” button the “SILENCE” LED would turn on . TEST LAMP: In normal status, press “TEST” button would have a lamp test. SILENCE SOUND: In fire or fault status, press “SILENCE” button would silence the alarm sound. RESET: In the “SILENCE” status,press “RESET” button once the repeater would return to the Normal Status.
$67.00TCZS5273 Detector remote indicator light...
TCMK5265 Addressable I/O Module non-pol...