The gas alarm controller is used to observe, control and maintain the gas detector from a distance. Any operation inside a controller has to be performed by a professional. All operations must comply with local regulations and site procedures. The controller is wall-mounted controller, which can be installed directly on the wall of instrument room, duty room or workshop. The channel input of the controller is standard (4 ~ 20) mA signal, corresponding to the corresponding range, LCD screen displays the concentration of the gas channel and alarm information. *There are 2 channels, 4 channels and 8 channels for optional. One channel can equip one gas detector to show the corresponding measured value of gas concentration. The instrument can be widely used in petrochemical, artificial gas, metallurgy, iron and steel, coking, electric power and other combustible gas in various industries. It is the ideal controller to ensure property and personal safety. System parameters: Display: LED screen Signal input: 1-8 channels 4-20mA standard current loop input, supporting 2-wire and 3-wire systems Working voltage: AC220V±15%,50Hz Using environment: Temperature: - 10 ℃, 50 ℃ Relative humidity: 10%~90%RH (non-condensing) Atmospheric pressure: 86kpa - 106kpa Response time < 30s Alarm volume > 75dB Error ≤±3%FS Dimension: 270mm*200mm*72mm (height*width*thickness) Extended functions: 4-20mA signal output/per channel Relay signal output/per channel 485 output/per channel (standard Modbus RTU protocol), can be connected to a computer for monitoring
$102.00Chemical security Flammable gas detector. Features: Display the concentration of the detected gas. Fault alarm, high and low alarm. Field screen display, including backlight, the characters are larger and clearer, and when the device alarms, the backlight turns red. Infrared remote control input, no need to open the cover, more convenient. Support three different sound and light outputs, corresponding to fault,low report and high report respectively. Zero adjustment, calibration and test functions. Output DC4-20mA standard signal. Support485, two bus, LoRa, flexible and changeable communication methods. Equipped with high-performance ARM microprocessor for easy operation. Three-way relay (250V5A) output, automatically open the fan and solenoid valve. It can store40 high and low alarm records in a cycle. The toxic gas detector can realize the conversion between mg/m and μ mol/mol. Specification: Power Power supply24V;flammable: ≤4W; oxygen/toxic: ≤3W range Flammable:(0-100) %LEL;Oxygen/Toxic: (0-1000) μmol/mol (determined by sensor) precision ±5%FS (determined by sensor) Minimum Flammable: 1%LEL; Toxic: 0.1 μmol/mol (determined by sensor) reading Response time Toxic:≤60seconds; flammable :≤30 seconds Sensor life 36months(determined by sensor) Sensor type Combustible:catalytic combustion type; toxic:electro chemical type (imported sensor) Detection Diffusion method Way of long-term continuous work working Connection M20*15malethreadexplosion-proofhose method Contact output Passive contact Capacity 5A/220V(3) Explosion- Ex d IICT6 Gb/Ex tD A21 IP67 T80℃ Proof mark Protection IP67 class Ambient Flammable: -40~70℃,15%~95%RH; temperature Toxic: -20~60℃;15%~95%RH and humidity weight ≤2kg Transmission ≤1200m(485 only ,two buses,4-20mA) distance output signal 4-20mA current signal, corresponding to full scale Replaceable important parts 1.Gas sensor and housing 2.Sound and light alarm light and shell 3.Infrared remote control 4.Supporting circuit board
$219.00Chemical security H2S gas detector. Features: Display the concentration of the detected gas. Fault alarm, high and low alarm. Field screen display, including backlight, the characters are larger and clearer, and when the device alarms, the backlight turns red. Infrared remote control input, no need to open the cover, more convenient. Support three different sound and light outputs, corresponding to fault,low report and high report respectively. Zero adjustment, calibration and test functions. Output DC4-20mA standard signal. Support485, two bus, LoRa, flexible and changeable communication methods. Equipped with high-performance ARM microprocessor for easy operation. Three-way relay (250V5A) output, automatically open the fan and solenoid valve. It can store40 high and low alarm records in a cycle. The toxic gas detector can realize the conversion between mg/m and μ mol/mol. Specification: Power Power supply24V;flammable: ≤4W; oxygen/toxic: ≤3W range Flammable:(0-100) %LEL;Oxygen/Toxic: (0-1000) μmol/mol (determined by sensor) precision ±5%FS (determined by sensor) Minimum Flammable: 1%LEL; Toxic: 0.1 μmol/mol (determined by sensor) reading Response time Toxic:≤60seconds; flammable :≤30 seconds Sensor life 36months(determined by sensor) Sensor type Combustible:catalytic combustion type; toxic:electro chemical type (imported sensor) Detection Diffusion method Way of long-term continuous work working Connection M20*15malethreadexplosion-proofhose method Contact output Passive contact Capacity 5A/220V(3) Explosion- Ex d IICT6 Gb/Ex tD A21 IP67 T80℃ Proof mark Protection IP67 class Ambient Flammable: -40~70℃,15%~95%RH; temperature Toxic: -20~60℃;15%~95%RH and humidity weight ≤2kg Transmission ≤1200m(485 only ,two buses,4-20mA) distance output signal 4-20mA current signal, corresponding to full scale Replaceable important parts 1.Gas sensor and housing 2.Sound and light alarm light and shell 3.Infrared remote control 4.Supporting circuit board
$216.00Measuring Range of 0~100% LEL combustible gas leakage alarm. This detector can be wall-mounted and cabled easily (AC 220V-plug, DC 12V solenoid valve-plug). It is stable and don't need commission, with wide range ofenvironmental adoption. JT-TC521 independent detector is widely used in houses, hotels, apartments or other places that combustible gas may exist. This detector can monitor natural gas, liquefied petroleum gas and artificial gas. Features ● Equip with high-quality gas sensor, reliable and corresponding. ● The intelligent algorithm of the microprocessors can compensate for the drift of gas sensor. ● The precision temperature sensor is a supplement of the monitoring of the environment temperature, which completely eliminates false alarms. ● LEDs indicate the detector status of normal, alarm and fault. ● The shell of the detector use fire-resistant ABS engineering plastic, clean and generous. Technical Specifications 1) Operating power: AC 220V 2) Standby current: 6 mA 3) Alarming current: 7 mA 4) Ambient temperature: -10℃~+50℃ 5) Operating humidity: ≤95%RH 6) Sound level: >75dB 7) Pressure: 86kPa-106kPa 8) First stabilization period: 3 min 9) Expiration date of sensor: >5 years(in clean air) 10) Alarm threshold: methane: 8% LEL 11) Detecting gas: available for natural gas, artificial gas, liquefied petroleum gas and many other kinds of combustible gas. 12) Output contact: active contact, available for one-way pulse electromagnetic valve of DC 12V; the drive capability of electromagnetic valve: 1000 μF capacity discharge. 13) Wiring: ①White plug: Connecting DC 12V solenoid valve ②White terminal: Connecting AC 220V 14) Dimension: 120mm×86mm×48mm
$16.50Detect natural gas, manufactured gas, liquefied petroleum gas and other combustible gas. JT-TC516 Combustible Gas Detector With Measuring Range of 0~100% LEL. It adopts advanced normal temperature semiconductor gas sensor, microprocessor combined with precision temperature sensor. It can intelligently compensate the drift of gas sensor, and the environmental adaptation range is wide. ▪ Electronically coding ▪ Ceiling-mounted ▪ Electronically addressed ▪ Widely used in homes, hotels, apartments and other places where combustible gas exists ▪ Detect natural gas, manufactured gas, liquefied petroleum gas and other combustible gas ▪ Active contact, applying to DC12V Single-phase dc pulse solenoid valve; the drive capability of a solenoid valve: 1000µF capacity discharge Technical Specifications Operating voltage: DC24V Standby current: 21mA Alarm current: 28mA Operating Environment: Temperature: -10°C~+50°C,Relative Humidity: ≤95% Sound level: >75dB Pressure: 86kPa-106kPa Dimension: 100mm×51mm (with base) First stabilization period: 3 min Expiration date of sensor: >5 year(s in clean air) Alarming threshold: methane: 8% LEL Detecting gas: available to detect natural gas and many other kinds of combustible gas containing methane. Encoding mode: addressable Wiring: ①Terminal No. 1, 4: DC 24V input power line, non-polarized. ②Terminal No. 2, 3: non-polarized input signal cable, connecting the loop of control panel JT-TC516 Addressable Combustible Gas Detector should work with gas monitor panel JB-KR-TC5306
$18.00Equipped a color LCD and a printer available for all information when alarms, errors or other operations occur. It finds that combustible gas leaks in industrial environment and daily living environment. When combustible gas alarm system detects that the concentration of combustible gas reaches the alarm value set by the alarm system, the combustible gas alarm will send out sound and light alarm signals to remind people to take safety measures such as evacuation, forced air exhaust and equipment shutdown. ▪ Color menu display ▪ Max 1 loop ▪ Networking Function ▪ Wall-mounted structure ,compact and exquisite ▪ Built-in printer ▪ Strong anti-interference capability Technical Specifications Mains supply: AC220V (3A),Voltage range: +10%~-15% Standby battery: 12V/7AH sealed lead acid battery *2 LCD screen size: 4.3-inch color LCD screen Operating Environment: Temperature: 0°C~+40°C;Relative Humidity: ≤95%, non-condensing Capacity: 255 addressable points Communication Interface: RS485、CAN、USB Dimension (L×W×H): 320mm×120mm×400mm
$390.00JT-TC518 Addressable Combustible Gas Detector of Measurement Range 0-100%LEL It adopts advanced semiconductor gas sensors using at room temperature and microprocessors in conjunction with precision temperature sensor, which can compensate for the drift of intelligent gas sensor. This detector can be wall-mounted and cabled easily. It is stable and don't need commission, with wide range of environmental adoption. JT-TC518 addressable detector is widely used in houses, hotels, apartments or other places that combustible gas may exist. This detector can monitor natural gas and other combustible gas containing methane. Features ● Equip with high-quality gas sensor, reliable and corresponding. ● The intelligent algorithm of the microprocessors can compensate for the drift of gas sensor. ● The precision temperature sensor is a supplement of the monitoring of the environment temperature, which completely eliminates false alarms. ● LEDs indicate the detector status of normal, alarm and fault. ● The shell of the detector use fire-resistant ABS engineering plastic, clean and generous. Technical Specifications 1) Operating power: DC 24V 2) Standby current: 21 mA 3) Alarming current: 28 mA 4) Ambient temperature: −10℃〜+50℃ 5) Operating humidity: ≤95%RH 6) Sound level: >75dB 7) Pressure: 86kPa-106kPa 8) First stabilization period: 3 min 9) Expiration time of sensor: >5 years(in clean air) 10) Alarming threshold: methane: 8% LEL 11) Detecting gas: available to detect natural gas and many other kinds of combustible gas containing methane. 12) Output contact: active contact, available for one-way pulse solenoid valve of DC 12V; the drive capability of solenoid valve: 1000 μF capacity discharge 13) Encoding mode: addressable 14) Wiring: ①White plug: Connecting DC 12V solenoid valve ②Black line: Connecting DC 24V ③White line: Connecting the loop of control panel 15) Dimension: 120mmX86mmX48mm
$20.00TCZS5273 Detector remote indicator light...
TCMK5265 Addressable I/O Module non-pol...
© Copyright 2018~2025 by vedard.com