FW6000 Intelligent Fire Alarm Control Panel (FACP) is the new-generation fire alarm control unit designed for application in small and medium projects. It is wall-mounted type and has the advantages of powerful function, high reliability and flexible configuration. The panel is equipped with a LCD monitor to display all the information on fire alarms, faults and various operations, which can be printed out by the built-in printer. FW6000 is a one-loop control panel with maximum 240 points, which can work together with all FW 3 series field devices. Features: 1. This FACP uses two-wire bus system to control up to 240 addressable devices. 2. Wall mount design makes it easy to use and operate. 3. The FACP is composed of a main control module, a driver board and a communication board. 4. This FACP is compatible with the complete range of the FW series fire alarm devices like intelligent detectors, manual call point, input module, I/O module etc. 5. This FACP adopts windows-based operation menus, which are convenient and easily understood. 6. All the system functions can be realized just by simple operation to select the corresponding numbers or move the cursor. 7. The fire alarm sent out by this FACP is not only visible & audible, it can also be displayed on the LCD screen and be printed out by the built-in printer simultaneously, meanwhile, it can be recorded in the history log as well. Specification: 1. Primary AC Power supply: 220VAC 50/60Hz 2. Main supply output voltage (VDC): 27VDC & 32VDC 3. Mainy supply output current: 2.5A at 27VDC and 3A at 32VDC 4. Minimum battery size: 2*12V required 4Ah 5. Battery charging voltage (VDC): 27VDC 6. Battery charging current: 700mA 7. COM-SG connector voltage output: 1Amp @ 24VDC 8. DC24V connector voltage output: 1Amp @ 24VDC 9. COM-SG End of Line resistor (Ohms): 10K 10. COM-HJ contacts capacity: 2Amp @ 24VDC 11. COM-HJ End of Line Resistor (Ohms):10K 12. Computer Interface: USB 13. Display: Graphical LCD 128*64 14. Operating Humidity Range: 10% to 93% relative humidity, Non-condensing. 15. Operating Temperature Range: -10C to 50C 16. FACP Dimension (L*W*D): 330mm*120mm*400mm 17. FACP Neight weight: 7.8kg
$461.00LPCB(EN54-2/4) CE approval addressable fire alarm control panel new technology with Black box function etc. Color menu display Intelligent bus control mode; max 255 addressable points per loop, max 4 loops, max 48 zones Loop card type design:1-4 loop card can be selected Glass fuse per loop Black box function Independent controlling password for the specially needed gas recharging units Self-design loop protocol Wall-mounted structure, compact and exquisite Language: simplified Chinese and English Approvals:LPCB(EN54-2/4) CE Technical Specifications Mains supply AC 230V (50HZ),Voltage range: +10%~-15% Standby battery 12V/12AH sealed lead acid battery *2 LCD screen size 7-inch color LCD screen Operating Environment Temperature: -5°C~+50°C;Relative Humidity: ≤95%, non-condensing Capacity 1020 addressable points Communication Interface RS232、RS485、C A N、U S B Dimension (L×W×H) 420mm×140mm×560mm Output Five output. Fault output. 24V power output. Loop output
$990.00 $810.00Standard configuration of 2 loops addressable fire alarm control panel FW9000. ETL approval intelligent fire alarm control panel with good performance, flexible configuration and easy operation. Check information of alarm, fault and other operations is displayed by big LCD screen and can be printed by its built-in printer. The control panel supports 484 points two loops. If change installation, it can be extended to 64 loops. It can work with FW brand all types smoke detector, heat detector, manual call point, sounder strobes, modules and fireman's control panels to realize automatic fire alarm and control. Features: 1. The fire alarm panel has 2 loops in standard configuration and one loop can access 242 points. (FW devices). If the installation mode is changed, the extended loop can be extended to 64 loops and connected to 15488 detectors. 2. The panel has 6 sets of direct start buttons, which correspond to 6 sets of DC24V output and 6 sets of feedback access contacts, and 24 sets of addressable start buttons. 3. The panel is equipped with two DC12V battery backup to ensure the system can operate normally without AC power supply. 4. The panel have one RS-232 interface for PC panel configuration tool. It has two RS485 communication port for other external device. 5. The panel is connected to the computer through RS232, and the loop information and linkage information can equipment. 6. The panel has micro printer and can automatically print out fire alarm information, fault information etc. Specification: 1. Primary AC power supply: 220VAC 50/60Hz 2. Main supply output voltage (VDC): 27VDC &32VDC 3. Main supply output current: 2.5A at 27VDC, 3A at 32VDC 4. Minimum battery size 2*12V, DC12V/7Ah 5. Battery charging voltage (VDC): 27VDC 6. Battery charging current: 700mA 7. Sounder connector voltage output: 1Amp at 24VDC 8. DC24V connector voltage output: 1Amp at 24VDC 9. Fire feedback input end line resistor (Ohms): 10K 10. Fire feedback input contacts capacity: 2Amp at 24VDC 11. Printer: Built-in microwave printer 12. Computer interface: USB & RS232 13. Display: Graphical LCD 320*240 14. Operating humidity Range: 10%-93% relative humidity non-condensing. 15. Operating temperature: -10 to 50C 16. FACP dimension (L*W*D): 470mm*130mm*420mm 17. FACP net weight: 16.8kg
$568.00Works with TC series addressable fire alarm system Intelligent heat detector Advanced single-chip microcomputer technology Non-polarized two-wire Indoor garage, kitchen, boiler room, generator room, drying room and other places Approval: LPCB(EN54-5) CE Technical Specifications Operating voltage Loop 24V(18.5V~26V) Operating current Standby current: ≤0.3mA; Alarm current: ≤0.8mA Operating Environment Temperature: -10°C~+50°C; Relative Humidity: ≤95%, non-condensing Indicator Red,Flashes when polling,Illuminates in alarm Ingress protection rating IP33 Material and color of enclosure ABS; Milky white Coding method Electronically coding Code range 1~255 Weight About 110g Mounting hole distance 60mm Dimension 100mm×50mm (with base)
$14.90The gas alarm controller is used to observe, control and maintain the gas detector from a distance. Any operation inside a controller has to be performed by a professional. All operations must comply with local regulations and site procedures. The controller is wall-mounted controller, which can be installed directly on the wall of instrument room, duty room or workshop. The channel input of the controller is standard (4 ~ 20) mA signal, corresponding to the corresponding range, LCD screen displays the concentration of the gas channel and alarm information. *There are 2 channels, 4 channels and 8 channels for optional. One channel can equip one gas detector to show the corresponding measured value of gas concentration. The instrument can be widely used in petrochemical, artificial gas, metallurgy, iron and steel, coking, electric power and other combustible gas in various industries. It is the ideal controller to ensure property and personal safety. System parameters: Display: LED screen Signal input: 1-8 channels 4-20mA standard current loop input, supporting 2-wire and 3-wire systems Working voltage: AC220V±15%,50Hz Using environment: Temperature: - 10 ℃, 50 ℃ Relative humidity: 10%~90%RH (non-condensing) Atmospheric pressure: 86kpa - 106kpa Response time < 30s Alarm volume > 75dB Error ≤±3%FS Dimension: 270mm*200mm*72mm (height*width*thickness) Extended functions: 4-20mA signal output/per channel Relay signal output/per channel 485 output/per channel (standard Modbus RTU protocol), can be connected to a computer for monitoring
$102.00Chemical security Flammable gas detector. Features: Display the concentration of the detected gas. Fault alarm, high and low alarm. Field screen display, including backlight, the characters are larger and clearer, and when the device alarms, the backlight turns red. Infrared remote control input, no need to open the cover, more convenient. Support three different sound and light outputs, corresponding to fault,low report and high report respectively. Zero adjustment, calibration and test functions. Output DC4-20mA standard signal. Support485, two bus, LoRa, flexible and changeable communication methods. Equipped with high-performance ARM microprocessor for easy operation. Three-way relay (250V5A) output, automatically open the fan and solenoid valve. It can store40 high and low alarm records in a cycle. The toxic gas detector can realize the conversion between mg/m and μ mol/mol. Specification: Power Power supply24V;flammable: ≤4W; oxygen/toxic: ≤3W range Flammable:(0-100) %LEL;Oxygen/Toxic: (0-1000) μmol/mol (determined by sensor) precision ±5%FS (determined by sensor) Minimum Flammable: 1%LEL; Toxic: 0.1 μmol/mol (determined by sensor) reading Response time Toxic:≤60seconds; flammable :≤30 seconds Sensor life 36months(determined by sensor) Sensor type Combustible:catalytic combustion type; toxic:electro chemical type (imported sensor) Detection Diffusion method Way of long-term continuous work working Connection M20*15malethreadexplosion-proofhose method Contact output Passive contact Capacity 5A/220V(3) Explosion- Ex d IICT6 Gb/Ex tD A21 IP67 T80℃ Proof mark Protection IP67 class Ambient Flammable: -40~70℃,15%~95%RH; temperature Toxic: -20~60℃;15%~95%RH and humidity weight ≤2kg Transmission ≤1200m(485 only ,two buses,4-20mA) distance output signal 4-20mA current signal, corresponding to full scale Replaceable important parts 1.Gas sensor and housing 2.Sound and light alarm light and shell 3.Infrared remote control 4.Supporting circuit board
$219.00works with TC series addressable fire alarm system Hotel, restaurant, warehouse, library, office building, teaching building fire security equipment smoke sensor fire detection system. Infrared scattering principle Non-polarized two-wire Drift compensation and fault detecting function Reporting dirt fault Hotel, restaurant, warehouse, library, office building, teaching building, power plant and other places Approvals:LPCB(EN54-7) CE Technical Specifications Operating voltage Loop 24V(18.5V~26V) Operating current Standby current: ≤0.3mA;Alarm current: ≤0.8mA Operating Environment Temperature: -10°C~+55°C,Relative Humidity: ≤95%, non-condensing Indicator Red,Flashes when polling,Illuminates in alarm Ingress protection rating IP23 Material and color of enclosure ABS; Milky white Coding method Electronically coding Code range 1~255 Weight About 110g Mounting hole distance 60mm Dimension 100mm×51mm (with base)
$14.90DC24V LPCB Approved resetable manual fire alarm call point Addressable fire alarm button works with TC series addressable fire alarm system. Installed in public places; when there is a fire, pressing the frangible element on this MCP can send fire signal to fire alarm control panel Alarm by pressing, reset by a special key Non-polarized two-wire to the control panel Reusable Approvals:LPCB(EN54-7) CE Technical Specifications Operating voltage Loop 24V(18.5V~26V) Operating current Standby current: ≤0.2mA;Alarm current: ≤0.8mA Operating Environment Indoor Temperature: -10°C~+55°C;Relative Humidity: ≤95%, non-condensing Indicator Red. Flashes about every 3s when polling;Illuminates after in alarm Coding method Electronically coding Code range 1~255 Material and color of enclosure ABS; Red Weight About 120g (with base) Mounting hole distance 60mm Dimension (L×W×H) 95mm×44mm×95mm (with base)
$14.90Chemical security H2S gas detector. Features: Display the concentration of the detected gas. Fault alarm, high and low alarm. Field screen display, including backlight, the characters are larger and clearer, and when the device alarms, the backlight turns red. Infrared remote control input, no need to open the cover, more convenient. Support three different sound and light outputs, corresponding to fault,low report and high report respectively. Zero adjustment, calibration and test functions. Output DC4-20mA standard signal. Support485, two bus, LoRa, flexible and changeable communication methods. Equipped with high-performance ARM microprocessor for easy operation. Three-way relay (250V5A) output, automatically open the fan and solenoid valve. It can store40 high and low alarm records in a cycle. The toxic gas detector can realize the conversion between mg/m and μ mol/mol. Specification: Power Power supply24V;flammable: ≤4W; oxygen/toxic: ≤3W range Flammable:(0-100) %LEL;Oxygen/Toxic: (0-1000) μmol/mol (determined by sensor) precision ±5%FS (determined by sensor) Minimum Flammable: 1%LEL; Toxic: 0.1 μmol/mol (determined by sensor) reading Response time Toxic:≤60seconds; flammable :≤30 seconds Sensor life 36months(determined by sensor) Sensor type Combustible:catalytic combustion type; toxic:electro chemical type (imported sensor) Detection Diffusion method Way of long-term continuous work working Connection M20*15malethreadexplosion-proofhose method Contact output Passive contact Capacity 5A/220V(3) Explosion- Ex d IICT6 Gb/Ex tD A21 IP67 T80℃ Proof mark Protection IP67 class Ambient Flammable: -40~70℃,15%~95%RH; temperature Toxic: -20~60℃;15%~95%RH and humidity weight ≤2kg Transmission ≤1200m(485 only ,two buses,4-20mA) distance output signal 4-20mA current signal, corresponding to full scale Replaceable important parts 1.Gas sensor and housing 2.Sound and light alarm light and shell 3.Infrared remote control 4.Supporting circuit board
$216.00Audio and visual alarm device used to warn people in field It works with TC series addressable fire alarm system. It has LPCB approval Installed in public places A kind of audio and visual alarm device used to warn people in field when fire occurs Four wires:non-polarized signal two-wire, and non-polarized DC24V power two-wire Built-in microprocessor Self-diagnostic function Electronically coding Approvals: LPCB(EN54-3) CE Technical Specifications Operating voltage Loop: 24V (16V~28V);Power: DC24V (DC19V~DC28V) Standby current Loop: ≤0.2mA;Power: ≤0.5mA Active current Loop: ≤1.5mA;Power: ≤50mA Operating Environment Indoor (Non-residential);Temperature: -10°C~+50°C; Relative Humidity: ≤95%(40±2°C) Sound level 80dB~115dB (A weighted) Pitch shift periodic 3.5S~4.5S Basic flashing frequency 1Hz~2Hz Weight 200g Dimension (L×W×H) 115mm×55.3mm×140mm
$16.80Suitable for using with 2 wire conventional fire alarm control panel. 80dB~115dB Fire evacuation sound and light alarm device Fire beacon DC24V power two-wire, non-polarized TCSG5228F Conventional Sounder Strobe TCSG5228F Conventional Sounder Strobe adopts 2 wires (24V power). It is mainly installed in public places. It generates a kind of optical and visual alarm used to warn people in field when fire occurs. With plug-in structure, reliable performance, simple and easy installation, attractive appearance, it has high reliability and good anti-interference functions. It connects to the fire alarm control panel by using an addressable linkage control module. More details and instruction can be found at fire alarm system Features 1. DC24V power two-wire, non-polarized. 2. After activated, it will generate strong audible and visual alarm signal. 3. Attractive appearance, convenient and reliable installation. Technical Specifications 1. Operating voltage: Power bus voltage: DC24V Range allowed: DC19V~DC28V 2. Operating current: Power action current≤50mA 3. Operating environment: Temperature: -10°C~+50°C Relative Humidity: ≤95 %( 40±2 °C) Indoor (Non-residential) 4. Dimension: 140mm×115mm×55.3mm (L×W×H) 5. Alarm voice: 80dB~115dB (A weighted) 6. Flashing frequency: 1Hz~2Hz 7. Cycle of changing level tone: 3.5S~4.5S 8. Weight: 200g 9. Standard: GB 26851-2011
$10.50TCSB5214H TC fire alarm system series LPCB approval addressable 2-wire bus type Voltage: Loop DC24V(16V-28V) Digital Manual Call Point (With Jack) (MCP) is installed in public places. The MCP contains a phone jack. And when there is a fire, pressing the frangible element on this MCP can send fire signal to Fire Alarm control panel. After receiving the signal, the control panel will show address information of the MCP and generate alarm sound. Insert the Fire Telephone handle into the phone jack, and then communicate the fire telephone panel. Features 1.Plug-in structure. Simple and convenient installation. Alarm by pressing, reset by a special key. 2.Pressing the frangible element and it can provide independent output contact through the MCP. And it can directly control other peripheral devices. 3.Microprocessor processes signal and digital signal communicates the Fire Alarm Control Panel. Stable and reliable work, good ability to inhibit electromagnetic interference. 4.Electronically addressed. The address can be modified in field. Easy and reliable for commissioning. Technical Specifications 1.Operating voltage Signal bus voltage: loop 24V 2.Operating current Standby current: ≤ 0.2mA Alarm current: ≤ 0.8mA 3.Type of initiating part: Reusable 4.0Initiating mode: Pressing the frangible element manually 5.Resuming mode: Manually resumed by a special key 6.Indicator Running/fire LED: Red. Flashes every 3s when polling. Illuminates after alarming. Fire telephone: Red. Flashes every 5s. 7.Programming mode Electronically addressed (address range: one address within 1~255). 8.Wiring Non-polarized signal two-wire 9.Operating environment Class: indoor Temperature: -10°C~+55°C Relative Humidity: ≤95%, non-condensing 10.Dimension Diameter: 90mm×90mm×42 mm (with base) 11.Material and color of enclosure: ABS; red 12.Weight: about 120g(with base) 13.Mounting hole distance: 60mm 14.Standard: GB 19880-2005 Call Point with Jack
$15.90Addressable Single I/O Module LPCB intelligent Module Designed to connect with linkage devices of fire alarm control panel, such as exhaust valve, air valve, fire damper etc., and can receive feedback signal from device Non-polarized two-wire Active and passive output The input terminal can be in field set to normally open detecting wire or self-feedback mode, which can be connected with passive contact Approvals: LPCB(EN54-18) CE Technical Specifications Operating voltage Loop:24V (18.5V~26V);Power: DC24V (DC19V~DC28V) Standby current Loop: ≤0.2mA;Power: ≤2mA Starting current Loop: ≤2mA;Power: ≤22mA Operating Environment Temperature: -10°C~+55°C;Relative Humidity: ≤95%, non-condensing Output capacity Passive:Capacity: DC30V/3A;Contact resistance in normal condition: 100kΩ;Closed when activated;Suitable for DC or AC12V~48V;Active output: DC24V/1.5A Indicator Red,Input indicator,Flashes when polling,Illuminates in action,Output indicator,Illuminates in action Coding method Electronically coding Code range 1~255 Material and color of enclosure ABS; Porcelain white Weight About 147g (with base) Mounting hole distance 60mm Dimension (L×W×H) 86mm×38mm×86mm (with base)
$16.00NAJ2214 Addressable Fire Extension Telephone handle works with TCSB5214H or same brand telephone jack It is a bus communication device special for fire protection system. The extension can transmit and receive signals with a Fire Telephone control panel. It is suitable for hotels, restaurants, office buildings, teach buildings, banks, warehouses, libraries, computer rooms and switching rooms. In traditional fire management, some information is managed in the form of paper files. Not only is the data record not comprehensive enough, but also it is difficult to consult and manage because data management is not applied. Tiancheng home safety all-wireless products are combined with the cloud platform, which can fully record and manage all the operation traces of equipment implementation. When the equipment fails, the system will automatically report it to the management party and the maintenance party, and the follow-up inspection and maintenance work will also be recorded in the whole process, so as to change the fire control work mode and further improve the fire control work management efficiency. Frequency Range: 300-3400Hz Operating Current: < 22mA Operating Environment: Temperature: - 10°C~+55°C; Relative Humidity: <95% Function: Matched with NAJ2213&NAJ2215 Dimension: 204 mmx 50mmX 38mm Mounting Hole Distance: 100mm Approval: CCCF
$13.5075dB~115dB Fire alarm conventional 2 wire suitable for all conventional fire alarm control panel TCSG5230F Conventional Sounder Strobe Voltage:Power: DC24V (19V~28V) Current:Standby Current: ≤0.5mA; Action Current: ≤15mA Operating Environment:Temperature: -10°C~+50°C;Relative Humidity: ≤95%(40±2°C) Sound Level:75dB~115dB (A weighted) Dimension:φ101mm×51mm Approval:CCCF Fire alarm system installation instruction and complete category can be downloaded at fire sounder
$9.50Alarm location display panel fire floor screen TCFS5089 TC brand LPCB approval professional intelligent addressable fire alarm system. Model No.: TCFS5089 It is used to display the fire location and related information of a certain floor or fire zone, and at the same time send out an sounder strobe alarm signals to inform people in nearby areas. * Display Fire Alarm position and information for certain floor or fire protection zone, give out audio and visual alarm signal to inform nearby personnel * Max 12 TCFS5089 Fire Display Panel per loop * Wiring: four bus system * Display range: any 512 alarm points within nearby 5 loops on its locating loop mainboard * Chinese comment display * Dimension: 180mm× 110mm× 40mm Voltage Loop : DC24V(16V-28V); Power: DC24V(20V-28V) Current Standby Current: loop:≤1.1 mA, Power: < 9mA; Alarm Current: Loop: ≤2mA, Power:≤45mA Operating Environment Temperature: -10°C~+50°C; Relative Humidity:≤9 5%, non-condensing Wiring Four-wired Dimension (LxWxH) 180mmX 110mmx40mm (with base) Approval CCCF, CE
$59.00