▪ The non-polar two buses are connected to the monitoring device to realize the communication and power supply functions at the same time. ▪ The address code is electronical, which can be written in advance by the electronic encoder. The engineering debugging is simple and reliable, which can also be set directly on the machine ▪ The microprocessor monitors the operation and transmits the status of the module to the monitoring device in both normal and alarm modes. ▪ Wire system: Non-polar connection to the signal bus of the monitoring device ▪ Line rated frequency: 50Hz/60Hz ▪ Dimensions: 92mm × 59mm × 110mm How to use the combined electric fire monitor detector? Each combined electric fire monitor detector is installed in one power distribution box. It has 8 channels and can accept input of residual current detection or high temperature detection signal. The residual current detectos' outlet loops and temperatures detectors' outlet loops will be funneled into the combined electric fire monitor detector. Then it connects to addressable electric fire monitor panel TC-5600. From the TC-5600, you can set the residual current alarm value. What can the combined electric fire detector do? How to wire and encode it?
$45.00Bus communication 1 loop or 2 loops electric fire monitor controller. This monitoring panel should work with DH12A, DH01B and DH230 electrical fire detectors to form an electrical fire monitoring system. Each detector has its own independent coded address and alarm information is reported to the control panel. At the same time, each channel of the bus device is disconnected or short-circuited, and the communication fault of the device is reported to the host JB-DH-TC5600 Electrical Fire Monitoring Equipment. Video guidance to set up the electric fire monitor system Features and specifications: Large screen LCD screen, various alarms, faults, status and other information are displayed. Residual current detector, temperature sensor alarm value has wide range adjustable, wide adaptability The detector is electronically coded by easy and convenient installation The function of interconnecting with our fire alarm system Maximum 2 loops with 255 electrical fire detectors per loop bus The casing meets the requirements of IP30 strictly, and all gaps and vents are no more than 2.5mm Controller dimensions (L × W × H): 360mm × 130mm × 480mm Working environment: -10°C~50°C, humidity<=95% Power: 50Hz, AC220V+10%-15% backup battery: 24V/3.3AH Weight: 8kg Executive standard: GB4717-2005
$310.00TC-DH01B-30 should be used with JB-DH-TC5600 to builds up electrical fire monitoring system. The detector can realize the function of leakage test, temperature test and output controlling by connecting with JB-DH-TC5600 electrical fire monitoring. It can also connect with many other kinds of residual current transformers to realize stable and reliable operation. Electrical fire monitoring system can effectively prevent electrical fire and reduce losses. How to wire and encode the residual current detector? Watch video guidance at Features: 1. Connect with monitoring devices through nonpolar two-line loop to realize the function of communication and power supply. 2. The addressable code is electrical code, which can be programmed by electrical programmer. It is convenient and reliable for engineering commission. 3. The operating situation is monitored by the microprocessor. The microproccessor will transmit the mode status of normality or alarming to monitoring devices. Specification: 1. Operationg Voltage: Pulse voltage of circuit loop : loop 24V, available range 16~30V 2. Operating current: standby current <=0.4mA alarm current <=0.7mA 3. Rated alarm ing current: 200mA ~1000mA step size 1mA 4. Encoding mode: electrical addressable mode. It takes one site on the loop. And an addressable code could be any in the range of 1~255. 5. Cabling: connecting with the monitoring devices through signal nonpolar two line loop. 6. Through-line aperture: 32.5mm; 7. main circuit rated working current: less than 100A 8. Dimensions: 122mm × 102mm × 45mm 9. It has LED indicators of working, alarm and fault 10. Workding environment: Temperature: -10°C ~+55°C Relative humidity≤95%(non-condensing) 11. Enclosuer material:ABS plastic 12. Ingress Protection Rating: IP30 Execution standard: GB 14287.2-2014
$24.00Two-line loop of electrical fire monitoring equipment, non-polarized. TC-DH01B-50 with specification as below: Through-line aperture 50.5mm main circuit rated working current: less than 250A Dimensions: 150mm × 102mm × 45mm It has three led indicators works as below: Running indicator: Green. It flashes when the communication of detector and control panel is working normally. Leakage alarm: Red. It goes out when the leakage tube is normal. It lights steadily when the leakage tube alarms. Leakage fault: Yellow. It goes out when the leakage tube is normal. It flashes when the leakage tube sensor is in trouble. Parameter setup: The encoding mode of this detector is electrical program which is convenient and efficient. Connect TCBM5023 electrical programmer with loop terminals of detector(non-polarized).Then the detector can read address and be programmed with addressable code. Please refer to Hand Held Programmer Installationand Operation Manual for details.
$32.00Through-line aperture: 73mm; main circuit rated operating current: less than 315A Dimensions: 160mm × 118mm × 45mm Works with 2-lines bus loop JB-DH-TC5600 Electrical Fire Monitoring Equipment. TC-DH01B-70 Residual current electrical fire monitoring detector has built-in processor can receive the signal from the transformer and handle those signals into two forms of normality and alarming, both of which will be transmitted to the electrical fire monitor control panel. Technical Features 1. Operating Voltage: Pulse voltage of circuit loop: Loop 24V Available range: 16V~30V 2. Operating current: Standby current≤0.4mA Alarming current≤0.7mA 3. Rated alarming current: 200mA~1000mA, step-size 1mA 4. Encoding mode: electrical addressable mode. It takes one site on the loop. And an addressable code could be any in the range of 1~255. 5. Cabling: connecting with the monitoring devices through signal nonpolar two-line loop. 6. Aperture of wires: 73mm 7. Rated operating current of main loop: less than 315A. 8. Rated frequency of wires: 50Hz/60Hz 9. Ambient environment: Temperature: -10℃~+55℃ Relative humidity≤95%, non-condensing 10. Dimension: 160mm×118mm×45mm 11. Enclosure material: ABS plastic 12. Ingress Protection Rating: IP30 13. Weight: about 1kg
$40.00Electrical fire monitoring system residual current detector. Built-in processor can receive the signal from transformer and handle those signal into two forms as normality and alarming, both of which will be transmitted to the electrical fire monitoring equipment. The microprocessor will transmit the mode status of normality or alarming to monitoring devices. How to use electric fire monitor equipment and how to install? Technical Features 1. Operating Voltage: Pulse voltage of circuit loop: Loop 24V Available range: 16V~30V 2. Operating current: Standby current≤0.4mA Alarming current≤0.7mA 3. Rated alarming current: 200mA~1000mA, step-size 1mA 4. Encoding mode: electrical addressable mode. It takes one site on the loop. And an addressable code could be any in the range of 1~255. 5. Cabling: connecting with the monitoring devices through signal nonpolar two-line loop. 6. Aperture of wires: 93mm 7. Rated operating current of main loop: less than 630A. 8. Rated frequency of wires: 50Hz/60Hz 9. Ambient environment: Temperature: -10℃~+55℃ Relative humidity≤95%, non-condensing 10. Dimension: 188mm × 145mm × 45mm 11. Enclosure material: ABS plastic 12. Ingress Protection Rating: IP30 13. Weight: about 1.3kg
$55.00Residual Current Electrical Fire Monitoring Detector TC-DH01B-J225 Through-line aperture: 225 × 56mm main circuit rated operating current: less than 630A Dimensions: 296mm × 166mm × 45mm Standard: GB14287.2-2014 "Electric Fire Monitoring Systems - Part 2: Residual Current Electric Fire Detectors” The Detector builds up an electrical fire monitoring system with our productions of JB-DH-TC5600 Electrical Fire Monitoring Equipment, TC-DH12A Combined Electrical Fire Monitoring Detector and TC-DH230 Combined Electrical Fire Monitoring Detector. The Detector can realize the function of leakage test, temperature test and output controlling by connecting with JB-DH-TC5600 Electrical Fire Monitoring Equipment through two-line loops. It can also connect with many other kinds of residual current transformers to realize stable and reliable operating. Electrical fire monitoring system can effectively prevent electrical fires and reduce losses. Technical Specifications: 1. Operating Voltage: Pulse voltage of circuit loop: Loop 24V Available range: 16V~30V 2. Operating current: Standby current≤0.4mA Alarming current≤0.7mA 3. Rated alarming current: 200mA~1000mA, step-size 1mA 4. Encoding mode: electrical addressable mode. It takes one site on the loop. And an addressable code could be any in the range of 1~255. 5. Cabling: connecting with the monitoring devices through signal nonpolar two-line loop. 6. Aperture of wires: 225mm×56mm 7. Rated operating current of main loop: less than 630A. 8. Rated frequency of wires: 50Hz/60Hz 9. Ambient environment: Temperature: -10℃~+55℃ Relative humidity≤95%, non-condensing 10. Dimension: 296mm×166mm×45mm 11. Enclosure material: ABS plastic 12. Ingress Protection Rating: IP30 13. Weight: about 3kg
$60.00Residual Current Transformer TC-DH01B-J325 Through-line aperture: 325 × 60mm main circuit rated operating current: less than 1000A Dimensions: 445mm × 220mm × 60mm Connected to the monitoring device JB-DH-TC5600 with a non-polar two buses, while achieving communication and power supply functions The address code is electronically encoded and can be written in advance by the electronic encoder. The engineering debugging is simple and reliable The microprocessor monitors the operation and transmits the status of the module to the monitoring device in both normal and alarm modes Wire system: non-polar connection to the signal bus of the monitoring device Residual current detector Specification: 1. Operating Voltage: Pulse voltage of circuit loop: Loop 24V Available range: 16V~30V 2. Operating current: Standby current≤0.4mA Alarming current≤0.7mA 3. Rated alarming current: 200mA~1000mA, step-size 1mA 4. Encoding mode: electrical addressable mode. It takes one site on the loop. And an addressable code could be any in the range of 1~255. 5. Cabling: connecting with the monitoring devices through signal nonpolar two-line loop. 6. Aperture of wires: 325mm×60mm 7. Rated operating current of main loop: less than 1000A. 8. Rated frequency of wires: 50Hz/60Hz 9. Ambient environment: Temperature: -10℃~+55℃ Relative humidity≤95%, non-condensing 10. Dimension: 445mm×220mm×60mm 11. Enclosure material: ABS plastic 12. Ingress Protection Rating: IP30 13. Weight: about 8kg
$120.00The detector can work independently or connect with JB-DH-TC5600 electrical fire monitoring equipment through two bus circuits, and realize the functions of leakage detection, temperature detection and output control. It works stably and reliably, and is connected with a variety of residual current transformers according to the magnitude of the over-line current. How to install electric fire monitoring system? Features 1.The Detector and the Electrical Fire Monitoring Equipment use non-polarized two-line system to connect. With mature technology, it is reliable in communication and convenient in cabling. 2. The Detector uses a high-performance CPU, intelligent algorithm and watchdog technology, highly efficient and reliable. 3. The Detector has a built-in passive output control which can connect with one or two loops to alarm leakage. 4. The Detector has the function of self-test which can test the screen and squealers working normally or not. 5. The Detector can set the residual current from 200mA to 1000mA of residual current transformers, which is high- precision detecting and widely used. It can be programmed with address and convenient for commission and maintenance. 6. The alarming temperature can be set from 45℃ to 140℃, high-precision detecting and widely used. It is convenient for commission and maintenance by the setup of addressable code and temperature. 7. The Detector has a good-looking appearance with intuitive showing of LCD information, simple operation and powerful functions, scalability and easy to installation. Technical Specification 1. Operating voltage: AC 220V 2. Operating current: ≤10mA 3. Alarming current: ≤25mA 4. Rated alarming current: 200mA~1000mA, step 1mA 5. Rated alarming temperature: 45℃-140℃, step 1℃ 6. Loop interface: Loop 24V, non-polarized 7. Capability of output terminal: 1A/AC125V,3A/DC24V 8. Response time: ≤10s 9. Rated frequency through the line: 50Hz/60Hz 10. The parameters of residual current transformer can be seen in chapter 5.3 11. Operating environment: Temperature: -10℃~+50℃ Relative Humidity: ≤95%, no condensation Altitude: <5000m 12. IP Grade: IP30 13. Weight: about 420g 14. Standard: GB 14287.2-2014“Electrical fire control system - Part 2: residual current electric fire detectors” GB 14287.3-2014“Electrical fire monitoring systems -Part 3: The temperature electric fire detectors” 4. Structure and Working Principle: 1. Refers to Fig.1 for the appearance of detector 2. Working principle The Detector receives the information from the sensor. When the information sent by the sensor reaches the setup value of threshold, the detector will send audible and visual alarm, and the screen will display the current alarm at the same time. If the Detector has been connect with the loop, the detector can upload alarm, faults and some other information to the electrical fire monitoring equipment and execute the order of the equipment.
$160.00TCZS5273 Detector remote indicator light...
TCMK5265 Addressable I/O Module non-pol...